Epever WiFi 2.4G DB9 B Panduan Memulai Cepat - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Adaptor Epever WiFi 2.4G DB9 B. Epever WiFi 2.4G DB9 B 2 halaman. Wifi 2.4g adapter
Juga untuk Epever WiFi 2.4G DB9 B: Panduan Memulai Cepat (2 halaman)

Epever WiFi 2.4G DB9 B Panduan Memulai Cepat
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
4. Operations
After successfully connecting the WiFi terminal to the controller, inverter, or
inverter/charger, the users remotely monitor the field devices through the PC,
large screen, or mobile phone.
Take the APP as an example to introduce remote monitoring through the
mobile phone.
Scenario 1: There is a local 2.4G WiFi network. The WiFi terminal
can upload the collected data to the EPEVER cloud automatically.
Operation Steps:
Step1: Turn on the WiFi switch on the mobile phone, and connect to the
local WiFi network (2.4G WiFi network is a must).
Step2: Open the APP and
click the "EPEVER Cloud"
icon to enter the login page.
Step4: Connect the WiFi
terminal to the 2.4G WiFi
network by searching for
the hotspots or scanning
the QR code.
Step3: Click the "Wifi On Cloud"
icon to jump to the network
connection page.
Step5: (Take the "Search for
hotspots" as an example.) Click
the hotspot's name, input the
password or tick the "Original
password" checkbox. Then
click the "Connect" icon.
3
Tel:+86-10-82894896/82894112/+86-752-3889706
Step6: Input the WiFi password,
and click the "Write" to connect
the WiFi network.
Step8: On the APP home page, click the "EPEVER Cloud" icon to jump to
the login page. Input the user name and password, click the "Sign In" to
enter the main page. Users remotely monitor the field devices by a mobile
phone. Note: Users can also operate the remote monitoring by the cloud
platform (https://iot.epsolarpv.com/).
Scenario 2: There is no local 2.4G WiFi network. The WiFi terminal
cannot upload the collected data to the EPEVER cloud.
Operation Steps:
Step1: Turn on the WiFi switch on
the mobile phone. Open the APP
and click the "Local" to enter the
"WiFi" connection page.
5. Specifications
Model
EPEVER WiFi 2.4G RJ45 A
Parameters
Input voltage
Power consumption
Enclosure
Communication method
Com. parameters
Working Frequency
Antenna gain
Environment temp.
Com. standard
Com. protocol
Com. port
Dimension
66.24* 51.28* 23.76mm
Net weight
6. Disclaimers
The warranty does not apply to the following conditions:
 Damage caused by improper use or inappropriate environment.
 The parameter setting exceeds the WiFi terminal's limit.
 Damage caused by working temperature exceeds the rated range.
 Unauthorized dismantles or attempted repairs.
 Damage caused by force majeure.
 Damage occurred during transportation or handling.
Any changes without prior notice!
Website:www.epever.com
Step7: After the connecting
shows 100%, click the "Confirm"
to return to the APP home page.
Step2: Click the WiFi terminal,
connect it to the APP by following the
prompts. Then enter the local
monitoring (only the downloaded
models can be monitored).
EPEVER WiFi 2.4G DB9 B
DC5V
Peak emission: 5V@100mA; Idle: 5V@40mA
IP54
RS485
9600 ~ 115200bps, 8N1
2.4~2.4835GHz
2.5dBi~ 5dBi
-40℃~ 85℃
EPEVER general communication standardV1-1.0
EPEVER IoT communication protocol V1.1
RJ45
DB9
101.2* 64* 26mm
37g
Version number: V1.4
4
38g