Diehl IZAR PULSE i Panduan Instalasi - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Alat Ukur Diehl IZAR PULSE i. Diehl IZAR PULSE i 8 halaman.

Diehl IZAR PULSE i Panduan Instalasi
2
INSTALLATION PRECAUTIONS
2.1 IDENTIFICATION
Ensure that IZAR PULSE i is compatible with the meter on which it is fitted:
(« Ti » or « Ha + Ti » marking). The installation of a non-return valve is not necessary as IZAR PULSE i is
able to manage backflow.
2.2 SECURING SYSTEM
IZAR PULSE i features 3 fastening hooks
(fig. 3) to fit the module on Diehl Metering's
modular inductive meter range.
A screw (fig. 4) tightens and loosens the
ring on the meter. This system makes the
assembly more secure while making it pos-
sible to remove the ring without damaging
the hooks.
Put the sealing label (delivered with the
radio module) on the clamping screw.
2.3

INSTALLATION

If there is a cover on the meter, remove it
by pushing out the hinge pin (fig. 5). If the
cover does not have a metal hinge, remove
it by hands.
Carefully clean the top of the register to
remove any traces of soiling.
Avoid solvents or abrasive cleaners as these could damage the plastic shell.
If necessary, use a cloth or wet sponge to clean.
Position IZAR PULSE i by aligning the hinges
up with each other (fig.6).
Press the ring onto the module with your
hands only, until it clicks into place.
Handle with care and do not use a mallet or
hammer as this may damage the electrical
components.
01/2015
Hooks
English
fig.3
fig.4
fig.5
fig.6
IZAR PULSE i | 3