Self-Calibration Adjustment
Self-Calibrating the side vertical laser lines (not the front
vertical laser line) for plumb
1. Locate the calibration port inside the battery
compartment.
2. Remove the rubber plug.
3. Unlock the compensator.
4. Use a 3mm hex head wrench.
5. Turn the calibration screw counter clockwise to move the top of the
side vertical lines to the back of the unit (towards the battery compart-
ment). Do not rotate the screw more than 4 rotations.
6. If the side vertical lines can not be brought into plumb after 4 rotations
of the screw, the unit will need to be serviced by Johnson Level & Tool.
Self-Calibrating the horizontal laser line and front vertical laser line
1. Locate calibration port on the side of the laser unit.
2. Remove the plastic screw.
3. Unlock the compensator.
4. Use a 3mm hex head wrench.
5. Rotate the screw counter clockwise to raise the left
side of the horizontal line and to adjust the top of the
front vertical line to the right. Do not rotate the screw more than 4
rotations.
6. If the laser lines can not be brought into calibration after 4 rotations
the unit will need to be serviced by Johnson Level & Tool.