Axor One 280 1jet Showerpipe 48790 7 Series Petunjuk Penggunaan/Petunjuk Perakitan - Halaman 3

Jelajahi secara online atau unduh pdf Petunjuk Penggunaan/Petunjuk Perakitan untuk Produk Pipa Axor One 280 1jet Showerpipe 48790 7 Series. Axor One 280 1jet Showerpipe 48790 7 Series 12 halaman.

S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
The arm of the shower head is intended only to hold the shower head. Do not load
it down with other objects!
Children as well as adults with physical, mental and ⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ The installation dimensions stated in these installation instructions are ideal for
people of approximately 1700 mm in body height. The dimensions can be altered
if required. In this case, pay attention to the fact that a change of installation height
will also change the minimum height, and that the altered mounting dimensions must
be taken into consideration.
⁄ The shower may only be connected downstream of a shut-off valve or sanitary
fitting.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The premounted filter insert must be used to ensure a normal flow of the shower and
to prevent dirt from entering through the pipes. Dirt entering can affect the function
and ⁄or lead to damages to the shower. Hansgrohe will not be held liable for this
type of damage.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Hot water temperature:
Thermal disinfection:
⁄ The product is exclusively designed for drinking water!
F A U L T
⁄ Insufficient water
A S S E M B L Y (see page 06 )
S Y M B O L D E S C R I P T I O N
max. 1 MPa
0,25 - 0,45 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
C A U S E
⁄ Supply pressure inadequate
⁄ Shower filter seal dirty
Do not use silicone containing acetic acid!
M A I N T E N A N C E (see page 10 )
⁄ The check valves must be checked regularly according to EN 806-5 in
accordance with national or regional regulations (at least once a year).
D I M E N S I O N S (see page 04 )
F L O W D I A G R A M (see page 05 )
 Hand shower
 Overhead shower
S P A R E P A R T S (see page 11)
XX = Colors
00 = Chrome Plated
14 = Brushed Bronze
25 = Brushed Gold-Optic
30 = Polished Redgold
31 = Brushed Redgold
33 = Polished Black Chrome
34 = Brushed Black Chrome
67 = Matt Black
70 = Matt White
80 = Stainless Steel Optic
82 = Brushed Nickel
95 = Brushed Brass
99 = Polished Gold-Optic
S P E C I A L A C C E S S O R I E S (order as an extra)
tile-matching-disk #94362XXX (see page 11 )
C L E A N I N G (see page 08 )
O P E R A T I O N (see page 10 )
R E M E D Y
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Clean filter seal between shower and hose
0 3
EN