Alphatron ALPHA BNWAS Panduan Pemasangan & Pengoperasian - Halaman 9
Jelajahi secara online atau unduh pdf Panduan Pemasangan & Pengoperasian untuk Sistem Keamanan Alphatron ALPHA BNWAS. Alphatron ALPHA BNWAS 16 halaman. Bridge navigational watch alarm system
A
ALPHA BNWAS
The AlphaBNWAS is easily operated by the buttons on the front panel.
Changes to time and on/auto/off mode can only be made when the key
switch is in the vertical position. The key cannot be removed when the
key is in the vertical position.
The 3 to 12 minute timer can be adjusted by pushing the time select
button. The on/auto/off mode can be selected by pushing the on/auto/off
select button. Activating the AlphaBNWAS will start the 3 to 12 minute
timer until it exceeds. The "reset" LED will start blinking and the internal
buzzer will sound for half a second giving a pre-alarm.
After 15 seconds the internal buzzer will pulsate continuously and the
relay contact for the (optional) bridge siren will sound.
If the officer on the bridge does not respond by operating the reset button
within 15 seconds, the backup officer will be alarmed and "call officer" LED
will light.
When the backup officer does not respond within the preset time (90-180
seconds) the entire crew will be notified by activating the general alarm.
This last stage can be adjusted with the 16-position switch (0-F) behind
the removable front panel.
The time is adjustable from 90 to 180 seconds in steps of 6 seconds
(0=90 , F=180 seconds). When the "Emergency" button is operated the
AlphaBNWAS will switch to "call officer" stage without activating acoustic
signalling on the bridge. The LEDs on the front panel can be dimmed by
holding the reset button for a few seconds.
9