Arcam MZ 12 Manual - Halaman 13
Jelajahi secara online atau unduh pdf Manual untuk Penguat Arcam MZ 12. Arcam MZ 12 18 halaman. Multi zone power amplifier
Introduction
This document describes the remote control protocol for controlling the MZ8/12 via the RS232 interface.
The document relates to MZ RS232 control protocol version 1.0. Any updates to this protocol will be posted on the Arcam Extranet website at
http://www.arcam.co.uk/extranet.
Serial Cable Specification
The cable is wired as a null modem:
Connector 1 pin
Connector 2 pin
2
3
3
2
5
5
Data transfer format
• Transfer rate: 38,400bps.
• 1 start bit, 8 data bits, 1 stop bit, no parity, no flow control.
Conventions
All hexadecimal numbers begin 0x.
Any character in single quotes gives the ASCII equivalent of a hex value.
<n> represents an unknown or variable number.
Command and response formats
Communication between the remote controller (RC) and the MZ8/MZ12 takes the form of sequences of bytes, with all commands and responses having
the same basic format. The MZ8/MZ12 shall always respond to a received command, but may also send messages at other times.
Each transmission by the RC is the following format:
<St> <Zn> <Cc> <Dl> <Data> <Et>
St (Start transmission): 0x21 '!'
Zn (Zone number): see below.
Cc (Command code): the code for the command
Dl (Data length): the number of data items following this item, excluding the ETR
Data: the parameters for the command
Et (End transmission): 0x0D
Each response by the MZ8/MZ12 is the following format:
<St> <Zn> <Cc> <Ac> <Dl> <Data> <Et>
St (Start transmission): 0x21 '!'
Zn (Zone number): see below.
Cc (Command code): the code for the command
Ac (Answer code): see below.
Dl (Data Length): the number of data items following this item, excluding the ETR
Data: the parameters for the response of length n. n is limited to 255.
Et (End transmission): 0x0D
The MZ8/MZ12 responds to each command from the RC within three seconds. The RC may send further commands before a previous command
response has been received.
rs232 control
Function
Rx Tx
Tx Rx
RS232 Ground
13