8-Stage Charging Steps:
Step 1: Diagnostics
Checks the battery voltage to make sure battery connections are good and the battery is in a
stable condition before beginning the charge process.
Step 2: Recovery
Initializes the Recovery process, if needed, the charger will perform deeply discharged or
sulfated (desolations) batteries by pulsing small amounts of current.
Step 3: Soft Start
Begins bulk charging process with a gentle (soft) charge.
Step 4-5: Bulk
The bulk charging process continues using both a High Rate or Medium Rate charge so that the
battery will return 80% capacity, and it will indicate by 25%, 50%, 75% charging level.
Step 6: Absorption
It brings the charging level to 90%, the battery charger will deliver small amounts of current to
provide a safe, efficient charge and limit battery gassing.
Step 7: Trickle
Battery is fully charged and ready to use, indicated by the 100% Charge LED illuminate solid
Green. In this step, the battery charger will only deliver enough current to keep the battery in
full charge. If the battery sends signal to the charger that requires more current, then the
battery charger will switch to maintenance stage.
Step 8: Maintenance
The Charger will continuously monitor the battery voltage to determine if a maintenance
charge should be initiated. If the terminal voltage falls below 6.4V (6V) and 12.8V (12V), the
charger will start the maintenance cycle until voltage reaches 7.2V (6V) and 14.4V (12V) and
Page | 9