Internal settings

Input sensitivity for mic inputs 1 and 2
screwdriver adjustable in the range 1.5 to 150 mV
default value is 1.5 mV (input sensitivity line 1 & 2 = 150 mV)
Adjustment of the basis configurations
power level
up to 1000 sqm, 8.8 A
rms
up to 500 sqm, 6.7 A
rms
up to 200 sqm, 4.3 A
rms
up to 100 sqm, 3.0 A
rms
Input LINE 2
Pin A+, A– balanced input
Pin V+
output 22 V DC, max. 1 A Pin
Pin GND
ground
*22 VDC output serves as power supply for external microphone to line pre-amplifiers.
axxent e.K. · Technologiezentrum Herzbachtal · Zum Wartturm 15 · 63571 Gelnhausen
fon: +49-6051-9165584 · fax: 9165585 · [email protected] · www.axxent.de
®
ISV 1090 Universal Induction Loop Amplifier
gain
via internal jumpers
gain jumper
current limit jumper
no
High: yes
no
High: no
yes
High: no
yes
High: no
current limiting
Mid: no
Mid: yes
Mid: no
Mid: no
User Manual
Low: no
Low: yes
Low: yes
Low: no