CIRCLE FITNESS E7 Panduan Servis - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Servis untuk Sepeda Latihan CIRCLE FITNESS E7. CIRCLE FITNESS E7 16 halaman.
Juga untuk CIRCLE FITNESS E7: Panduan Servis (9 halaman), Panduan Servis (20 halaman)

CIRCLE FITNESS E7 Panduan Servis
Item
Error Message
1.
MV VOLT OVERLOAD
2.
CMP CURR OVERLOAD
3.
CMP CURR OVERCURR
4.
SHORT CIRCUIT
5.
CURRENT STATE NG
Document:
Service Manual
Description:
Elliptical/Upright Bike/ Recumbent Bike
Model:
E7/B8/R8
Descriptions
CAUSE: The generator output voltage is overloaded.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output current of the generator is over 3amps
for 3 seconds.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output current of generator is over 3.5amps
for 1 second.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The IGBT of generator is short circuit.
SOLUTION:
- Stop peddling and wait for the power to shut down.
- Peddle to power up the console. If the error message
pops up again, replace the generator.
CAUSE: The output circuit of the generator is abnormal or
the coil did not connect to the controller.
SOLUTION:
- Check the coil connection.
- If coil connection is correct, replace the generator.
9
Display Type:
LED
Page:
9
of 16
Release Date:
2017/08/31