Arch Environmental Equipment CTS 9000 IRRD Panduan Pengoperasian dan Pemasangan - Halaman 2
Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Pemasangan untuk Sensor Keamanan Arch Environmental Equipment CTS 9000 IRRD. Arch Environmental Equipment CTS 9000 IRRD 4 halaman. Infra-red belt rip detection unit
INSTALLATION AND OPERATION
Tools Required For Installation:
The following tools are required for the installation of the belt misalignment unit :
1. Drill and extension.
2. ½ Inch Diameter Drill Bit.
3. 2 x 9/16 inch wrenches.
4. Adjustable Wrench.
5. 6mm flat screw driver.
6. 3mm flat screw driver.
Installation:
To install the CTS 9000 IRRD drill ½" holes into the conveyor structure matching the holes
on the CTS 9000 IRRD base plate, place the CTS 9000 IRRD on the conveyor structure
over the holes and bolt it down with supplied bolts. To connect the CTS 9000 IRRD, refer to
the CTS 9000 IRRD Control Box Wiring Diagram, and connect a cable to the COM terminal
and the N/O (Normally Open) or N/C (Normally Closed) contact depending on the
application.
Operation:
If an object is protruding through the belt as it passes the CTS 9000 IRRD it will break the
infrared beam and the unit will trip. If there is a longitudinal rip in the conveyor belt material
will fall onto the catch plate which then builds up and breaks the infra-red beam causing the
TYPE: CTS 9000 IRRD
ph 220VAC
ph 110VAC
N
WASH
LED1
N/O
COM
N/C
2
TRIP
LED2
LOCK
OUT
RESET P/B
LED1
1
WASH P/B
2
3
4