PROFESSIONAL SERVICE
If the previous "Self Help" checks fail to restore the performance, you should seek professional help.
The person who installed the shower is probably the best one to investigate and correct it and is
certainly the person to contact if you have had a problem in the guarantee period.
The following additional checklist is provided for the benefit of the qualified service person.
WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR
BEFORE REMOVING THE COVER TO MAKE CHECKS
Water too HOT
Water too COLD
Pump fails to
operate
Pump operates
but no water is
delivered
Water discharges
from pressure
relief valve
We offer a technical advisory service on the telephone to installers and other customers with
problems in the field.
RING 0870 9000 430 (UK Only) / RING +353 1 842 8222 (ROI Only)
Some spare parts (see later section) can be supplied against Credit or Debit cards.
RING 0870 9000 420 (UK Only) / RING +353 1 842 4833 (ROI Only)
Remember to quote the exact type of shower, as written on the front of the shower and on this
leaflet. The model and serial number are located on the bottom face of the shower.
Make a note of those numbers here, and be sure to quote them if you call for advice.
Model Number: _ _ _ _ _ _ _ _ _ _ _ / Serial Number: _ _ _ _ _ _ _ _ _ _ _
Note: You may be charged for a service call if you do not have the serial number.
WHAT TO DO IF THINGS GO WRONG (2)
Water flow restricted by a blockage in either the built-in pump filter or the
isolating valve filter.
Switch off the water supply at the isolation valve and fully isolate the
electricity supply, remove the appropriate filter, clean and replace (see
Diagrams 9a/b).
Check circuit through thermal cut-out.
Check circuit through microswitches on the pressure switch.
Check each element circuit.
Check tightness of electrical connections.
If the "power" light is illuminated, possible motor failure, replace if necessary.
If the "power" light remains off, check motor switch and replace if necessary.
Faulty motor switch (short circuit). Replace motor switch.
Incorrect alignment of motor switch camdrive.
In off position, the alignment marks on the cam drive (see Diagram 6) should
be centered about motor switch actuator.
Water flow restricted by a blockage in either the built-in pump filter or the
isolating valve filter.
Switch off the water supply at the isolation valve and fully isolate the
electricity supply, remove the appropriate filter, clean and replace (see
Diagrams 9a/b).
Check for cause of high pressure and remove it.
Blockage on outlet e.g. blocked shower handset.
Replace the pressure relief disc (not covered by guarantee).

CREDA AFTER SALES SERVICE

or contact your local distributor
or contact your local distributor
9