Digigram PCX-IP LW881e Panduan Pengguna - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Kartu Suara Digigram PCX-IP LW881e. Digigram PCX-IP LW881e 20 halaman. Professional multichannel sound cards with livewire connectivity

Digigram PCX-IP LW881e Panduan Pengguna
X­Topology installation
Under Windows XP and Windows Server 2003, it is possible to install the drivers without the DHS, so that controls like digital levels and
monitoring are accessible from the DirectSound controls. The driver package must then be installed as follows: MsiExec.exe /I
abcd.msi X_TOPOLOGY=1, where "abcd.msi" is to be replaced by the name of the driver package.
ASIO driver configuration
Note: Under 64­bit operating systems, and for most current ASIO applications (e.g. Cubase, Nuendo, etc...) you have the
 
 
 
choice between a 32­bit version and a 64­bit version when installing them. The 64­bit package of HR Runtime installs both a
 
   
 
10
In the "Custom Setup" window, the "Drivers for the HR boards" that can be
 
 
installed are listed.
The WDM DirectSound driver and the Digigram np driver are automatically
 
installed.
Items that can be optionally installed are:
Digigram Hardware Settings panel (DHS): installed by default. The DHS control
panel allows for adjusting digital level for input/ouptut channels, and monitoring
parameters. These settings cannot be controlled through DirectSound controls.
If the DHS is not installed, these settings are accessible for the DirectSound
controls.
This item is not selectable under Windows XP (see X­Topology installation)
Asio driver: installed by default
Wave MME driver: not installed by default
VX devices visible by default (to be selected in case the np based application is
not designed to detect the VX card­ the use of this option is specified by your
software application provider).
Click on Next once you have made your selection of items to be installed.
In the Window "Ready to Install the Program", click on Install to start copying the
 
 
files.
In case the User Account Control window prompts you to authorize the driver
 
installation, click on OK.
Driver files are then installed on the computer.
In case the "Digital Signature Not Found" message appears because a
 
non­Microsoft software is about to be installed, click on Continue.
Click Finish to complete the driver installation.
 
 
 
 
 
 
   
 
 
 
 
 
 
 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
PCX-IP LW881e, PCX-IP LW1221e
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   
 
 
 
   
 
 
 
 
 
 
 
   
 