Digikeijs DR4088CS Buku Petunjuk - Halaman 6

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Konverter Media Digikeijs DR4088CS. Digikeijs DR4088CS 14 halaman. Feedback module
Juga untuk Digikeijs DR4088CS: Buku Petunjuk (11 halaman), Manual (8 halaman), Buku Petunjuk (12 halaman), Buku Petunjuk (15 halaman)

Digikeijs DR4088CS Buku Petunjuk
DR4088RB-CS / OPTO
3.0 Programming
First, something fundamental about the R-Bus®:

The R-Bus® is always divided into two lines. The first string begins with module address 1 and the second string with module address 11.

A maximum of 160 feedback modules can be added to the R-Bus®.

The R-Bus® requires that a module consists of 8 feedback modules.

However, the DR4088RB contains 16 feedback modules.

The 1st DR4088RB is assigned the module addresses 1 and 2.

The 2nd DR4088RB is assigned module addresses 3 and 4.

etc.
3.1 Programming DR4088RB without further DR4088 at the S88N port
It is important that the DR4088RB-xx must receive the module address once (i.e. 1,3,5,7, etc.) so that the DR4018RB-xx knows which module address it
starts with. In addition, the DR4088RB-xx must be informed that it consists of 2 x 8 feedbacks.
3.1.1 Programming with the DR5000
1.
Open the DR5000 Tool
2.
Properties Call XN-FB Bus
3.
FB Call Programming Module
4.
Now just follow the instructions in the wizard.
Please refer to the instructions above for programming the number of modules.
Example:
DR4088RB-xx —>
DR4088RB-xx
Modul adress 1
Modul adresse 3
Number of modules = 2
Number of modules = 2
DR4088RB-xx —>
DR4088RB-xx —>
Modul address 1
Modul address 3
Number of modules = 2
Number of modules = 2
www.digikeijs.com
® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
2021-07-06
DR4088RB-xx
Modul address 5
Number of modules = 2
DR4088RB-xx
DR4088RB-xx
Modul address 7
Modul address 9
Number of modules = 2
Number of modules = 2
P 6