Cres Cor 1000-CH-D Series Panduan Pemasangan, Pengoperasian, dan Pemeliharaan - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Pemasangan, Pengoperasian, dan Pemeliharaan untuk Oven Cres Cor 1000-CH-D Series. Cres Cor 1000-CH-D Series 12 halaman.
FL-2340-D
Ovens
Rev. 0 (5/13)
Page 4 of 12
INSTALLATION INSTRUCTIONS (continued)
IDENTIFYING YOUR CABINET:
Look for this label on the back of your cabinet. This information is needed when calling for questions or service.
UPPER RIGHT CABINET CORNER
HOW TO INSTALL CABINETS:
1. Remove all packing material from the inside and all
vinyl from the outside of oven.
2. Place the oven in a well ventilated area on level floor.
Clearance requirements: 3" (76mm) at the back, 2"
(51mm) at the top, 1" (25mm) at both sides.
3. Install the pan slide racks on the sidewalls, if necessary.
4. Slide drip pan(s) onto the bottom of the compartment(s).
All models are rated at 208/240 Volts.
HOW TO REVERSE THE DOOR OPENINGS, IF
NEEDED:
1. Unscrew and remove the latch from the door and
magnetic strike from the cabinet.
2. Unscrew the hinges from the cabinet body and remove
door.
3. Remove the screws plugging the mating hinge, latch
and strike holes on the opposite sides of the cabinet
body and door.
4. Re-mount the hinges to the opposite side of the cabinet
and door.
5. Remount the latch and strike to the opposite side
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
5925 Heisley Road • Mentor, OH 44060-1833
R
5925 HEISLEY RD. MENTOR, OHIO 44060
MOD.
MOD.
1000CH
R
SER.
FAA-K5645C-001
FAA-K5645C-001
SER.
C
US
29
AMPS
AMPS
R
VOLTS
VOLTS
208/240
3000
WATTS
WATTS
COMMERCIAL COOKING APPLIANCE
MADE IN USA
CSA certified to UL 197 Rev. 9
FOR FIRST-TIME OPERATION ONLY:
A new oven needs to "burn off" factory oils and glue before
it's first use. Do NOT load food into oven until this has
been done!
1. Push switch to "ON"; the light will come on.
NOTE: The letters "LOTPR" (low temperature) will show
on the control panel until it reaches 140°F (60°C).
2. Press the "COOK" button.
3. Push down and turn the control knob to show 200°F.
Push the knob again to set the temperature. Run the unit
for one (1) hour.
4. Turn the unit off and let cool.
5. Wipe the inside clean with detergent and hot water.
DOOR VENT ADJUSTMENT:
Open the door(s) and move the vent tabs on the
inner door(s) as needed to release humidity.
WARNING
Air is VERY HOT when door is opened.
Hz.
Hz.
60
60
PH.
PH.
1
1