Cres Cor H137WSRR-C Series Panduan Petunjuk Pengoperasian dan Pemeliharaan - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian dan Pemeliharaan untuk Kulkas Cres Cor H137WSRR-C Series. Cres Cor H137WSRR-C Series 12 halaman. Companion holding cabinet
Juga untuk Cres Cor H137WSRR-C Series: Panduan Petunjuk Pengoperasian dan Pemeliharaan (12 halaman)

Cres Cor H137WSRR-C Series Panduan Petunjuk Pengoperasian dan Pemeliharaan
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WSRR-C Series Companion Holding Cabinet
TROUBLE-SHOOTING CHART:
FAILURE
1. Yellow light at switch
does NOT light.
2. Unit does not heat.
3. No humidity in cabinet.
4. Unit gets too hot or
won't shut off.
5. Blower does not work
or makes noise.
6. GFCI device trips.
GFCI (ground-fault circuit interrupter): A GFCI receptacle is a device that de-energizes a circuit when it
detects an unsafe fl ow of current to ground. The intention of a GFCI device is to minimize the potential for an
electrical shock
If cause is none of the above, refer to our list of Authorized Service Agencies.
POSSIBLE CAUSE
1a. Switch is "OFF".
1b. Cord unplugged from wall outlet.
1c. Circuit breaker/fuse to wall outlet blown.
2a. Temperature Control set too low.
2b. Switch is "OFF".
3a. Humidity Thermostat set too low.
3b. No water in water pan.
4a. Defective electrical parts. UNPLUG UNIT FROM WALL OUTLET.
5a. Defective blower.
6a. The insulation inside the heating elements may have absorbed some
moisture. This may have occurred if the cabinet has not been used for a
long period of time or during shipping and storage of the cabinet. Drain
the water pan if needed. Plug the cabinet into a non-GFCI outlet and set
the Temperature Control to 200° (93°C). Let the cabinet run for about 1
hour to dry out the heating elements from any moisture may have been
absorbed. If the circuit breaker trips, turn off cabinet, remove cord from
power source, and call the Factory Authorized Service Agent. After drying
the heating elements, plug cabinet into the GFCI receptacle; the cabinet
should run properly. If the GFCI trips, call the factory Authorized service
agent.
Companion
FL-2330
Holding Cabinet
Rev. 0 (2/07)
Page 5 of 10