3.3.

INITIAL STARTUP

To perform the initial start-up, proceed as follows:
Check to ensure that all input and output cables are properly connected and tightened.
Note: Use high quality coaxial cable and connectors. Properly install and solder all
connectors for reliability.
CAUTION:
Before applying power, make sure that the input and output of the
amplifier are properly terminated in 50 ohms. Do not operate the
amplifier without a load attached. Refer to Table 1-2 for input
power requirements. Excessive input power will damage the
amplifier.
NOTE:
The output coaxial cable between the amplifier and the antenna
must be 50 ohm coaxial cable.
2. Apply DC power to the amplifier. Verify that the power supply measures 13.8 ± 0.1VDC.
The fan will come on immediately for a few seconds and then turn off.
3. Visually check the indicators on each amplifier module, and verify the following:
a.
The DC PWR ON indicator (green) should be on.
b.
All ALARM LED indicators (red) should be off.
4. Turn on external exciter/transceiver and apply RF input signal. The fan should turn on
after approximately 3 seconds.
5. Turn off RF input signal. The fan should continue running, but turn off after
approximately 6-8 seconds.
Copyright Crescend Technologies
12
040003A001 Rev C