BYECOLD HH0606L Buku Petunjuk - Halaman 8

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pemanas BYECOLD HH0606L. BYECOLD HH0606L 10 halaman. Infrared heater panel with led light

Step 1. Once in 5+2 mode, Press and hold the SET button for 3-5 seconds until
Program icon ① and MON TUE WED THU FRI is displayed with ON and Time Icon
flashing on screen.
Step 2. Press ▲ button to adjust hour(+1hour/press) and press ▼ to adjust
Minute(+5minutes/press) to set the starting time of Program ①.
Step 3. Press the SET button once and OFF icon flashing on screen, Use ▲ Button
to adjust hour (+1hour/press) and press ▼ to adjust minute (+5minutes/press)
to set the ending time of Program ①.
Step 4. Press the SET button once again and set temperature icon flashing on
screen, Use ▲ or▼ button to set the desired temperature to be maintained for
program ①.
Step 5. Press the SET button to bring up Program ② of week days , repeat Step
2-5. And users can set up Program ③ and ④ in similar manner.
Step 6. After finishing setting Program ④, press the SET button to bring up SAT
and SUN setting, repeat step 2-5 to set Program① ② ③ ④ of weekends.
2) 1-7 Programming Mode
You can program the thermostat everyday with setting 2 groups of time interval
per day.
Once in 1-7 Mode, Press and hold the SET button for 3-5 seconds until Program
icon ① and MON is displayed with ON and Time icon flashing on screen, users
can follow the above step 2-4 to set On/Off time and desired temperature of
Program ① and ② from Monday to Sunday in sequence.
Tips
1). The default starting time is 00:00, the ending time is 00:00, and the default
operating temperature is 15 degrees.
2). If the user does not adjust the default On/Off time of 00:00, the programming
settings is invalid.
3). Running time of Program ① ② ③ ④ should not be overlapped, and the
ending time value of each program must be later than the starting time, otherwise
setting is invalid.
4). In 5+2 mode, if you do not want to set a mid-day heating period(Program ②
or ③ ), simply set the programs ② or ③ to a lower temperature than default
with very short intervals. An example is shown below.
5). The programmed time / temperature setting will be restored with the next
program entry in the memory.
6). Once finish setting up the programming mode, the thermostat will work under
programming mode ON even if the thermostat is turned off. The heating device
will be switched ON or OFF according to the programming setting.
Open Window Detection
The thermostat will automatically turn off the heating device if a sudden drop in
temperature in the room is detected.
Operation Instructions of LED Lighting Function
1.
Once thermostat is paired with device, Press ON/OFF button for LED light to
turn on/off the led light surrounding the panel, and long press ON/OFF
button to switch light color (Cold Light—Warm Light—Nature Light if
available).
2.
Press +/- to adjust the brightness, short press can adjust brightness to 100%,
75%, 50% and 25%, long press can adjust from 100% to 5%.
Notes
1
All settings need to be re-set after battery replacement.
2
Alkaline battery is recommended. If ALL buttons on the thermostat are not
working, try replacing the batteries.
3
Please do change the batteries with new ones once the screen battery symbol
gets flashing, or else it may result in halted/stuck/not working.
4
Check if set temperature is higher enough than room temperature first if the
heating can not be turned on by thermostat.
- 6 -