Cisco 9124 - mds multilayer fabric switch Catatan Rilis - Halaman 16

Jelajahi secara online atau unduh pdf Catatan Rilis untuk Beralih Cisco 9124 - mds multilayer fabric switch. Cisco 9124 - mds multilayer fabric switch 22 halaman. Mds 9000 series
Juga untuk Cisco 9124 - mds multilayer fabric switch: Spesifikasi (2 halaman), Lembar data (9 halaman), Spesifikasi (3 halaman), Panduan Konfigurasi (49 halaman), Catatan Rilis (48 halaman), Catatan Rilis (44 halaman), Catatan Rilis (36 halaman), Catatan Rilis (3 halaman), Catatan Rilis (40 halaman), Manual (16 halaman), Panduan Pemasangan Perangkat Keras (36 halaman)

Cisco 9124 - mds multilayer fabric switch Catatan Rilis
switch# config terminal
4. Enter the following command to enter the VSAN database:
switch(config)# vsan database
5. Enter the following command to enable the VSAN(s) that contain the Continuous Access
EVA and/or DRM fabric to src-dst-id loadbalancing:
switch(config-vsan-db)# vsan <1-4094> loadbalancing src-dst-id
switch(config-vsan-db)# exit
switch(config)# exit
6. Verify that src-dst-id is enabled for the desired VSAN by entering the following
command:
switch# show vsan <1-4094>
In the following example, VSAN 1 loadbalancing is set to src-id/dst-id
switch# show vsan 1
vsan 1 information
name: vsan1
interoperability mode: default
loadbalancing: src-id/dst-id
operational state: up
7. Type the following to copy the running configuration into the startup configuration:
switch# copy running-config startup-config
Refer to the Cisco MDS 9000 Family Fabric Manager Switch Configuration Guide to set
src-dst-id using Device/Fabric Manager.
Note: The running configuration overwrites the startup configuration.
C-SERIES MDS 9020 FABRIC MANAGEMENT
The C-series MDS 9020 can be managed through the CLI or the Cisco MDS 9000 Family
Fabric/Device Manager tool using Simple Network Management Protocol (SNMP). FabricWare
2.1(3) supports SNMP v1 and SNMP v2. When using Fabric/Device Manager with SNMP v3
enabled, all C-series MDS 9020 configurations must be saved using either the CLI or Device
Manager. In an environment where there is a co-existence of switches running SAN-OS and
FabricWare, Fabric Manager will only save SAN-OS configurations. To save MDS 9020 switch
configurations, the CLI or Device Manager must be used in order to avoid possible inconsistency
or fabric segmentation.
Note: WWPN (FLOGI) information can not be obtained for the MDS 9020 using Device Manager.
CHANGING PORT SPEED ON THE C-SERIES MDS 9020
If required, use the following CLI procedure to change the port speed setting on the C-series
MDS 9020:
16
state: active
MDS Multilayer Director & Multilayer Fabric Switches Release Notes