Commissioning
Connecting the device:
Connect power cable of the Cleaning and Embossing device to an appropriate power source and turn on
using the on/off switch on the back of the machine.
Connect the black wire to the black terminal connector on the front panel and connect the carbon stamp/
brush at the other end.
Connect the ground cable with the red mark on the red socket on the front panel and attach the
grounding clamp to the work piece.
Do not apply any external voltages to the component to be cleaned!
Do not use in wet areas and protect against moisture and splashes!
Cleaning with the brush
To remove the oxide layer, switch the machine on.
Ensure the brush is fitted with a brush head in good condition.
The brush is connected using the accompanying black ground cable to the black connector of the
machine. The red-marked ground wire must be connected to the work piece via the ground clamp.
Decant a little of the corresponding electrolyte (Electrolyte A / B / C / C Plus or LF) into the wide neck
receptacle provided and immerse the brush. Brush over the oxide layer to be treated until it has all
been removed.
After prolonged use the brush may become too warm. If this occurs, cool it in water bath,
or use a second brush.
Remove the electrolyte of the entire metal surface and neutralize the surface with a cloth soaked
in Neutralizer.
Tips for optimal cleaning
The BYMAT brushes are ideal for cleaning hard-to-reach areas. The short brush makes it easier
to get into sharp corners and around fine detail.
The longer brush is better for cleaning large areas.
To avoid short circuiting the machine, change the brush end before all the brush fibers are
depleted.
Working with chemicals can lead to hazards. It is required to wear an acid apron, tightly
fitting acid resistant goggles and gloves. It is also required to have sufficient extraction/
ventilation around the work piece or to wear a suitable respirator.
Please refer to the safety data sheets of the individual electrolytes.
NOTE: After switch off please wait min. 1 minute before restarting the machine.