Cisco AP776A - Nexus Converged Network Switch 5020 Catatan Rilis - Halaman 37

Jelajahi secara online atau unduh pdf Catatan Rilis untuk Beralih Cisco AP776A - Nexus Converged Network Switch 5020. Cisco AP776A - Nexus Converged Network Switch 5020 48 halaman. Cisco nexus 5000 series release notes release 4.1(3)n1(1) (ol-16601-01 h0, july 2009)
Juga untuk Cisco AP776A - Nexus Converged Network Switch 5020: Catatan Rilis (44 halaman), Catatan Rilis (26 halaman), Catatan Rilis (22 halaman), Panduan Referensi Cepat (14 halaman), Catatan Rilis (3 halaman), Catatan Rilis (26 halaman)

Cisco AP776A - Nexus Converged Network Switch 5020 Catatan Rilis
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

CFS Cannot Distribute All Call Home Information

In MDS NX-OS Release 4.2(1a), CFS cannot distribute the following Call Home commands that can be
configured with the destination-profile command:
The output of the show running-config callhome command shows configured Call Home commands:
switch# show running-config callhome
> version 4.1(3)
> callhome
>
>
>
>
>
>
>
>
>
>
>
>
>
>
When you attempt to apply these commands in the ASCII configuration, the following commands fail:
>
>
>
To work around this issue, issue these commands after the commit command.

Availability of F Port Trunking and F Port Channels

Trunking F ports and trunking F port channels are not supported on the following MDS 9000
components:
Trunking F ports, trunking F port channels and regular F port channels are not supported on the following
MDS 9000 components:
For configuration information, refer to the "Configuring Trunking" section in the Cisco MDS 9000
NX-OS Interfaces Configuration Guide.
OL-19964-02
destination-profile profile_name transport-method
destination-profile profile_name http
email-contact [email protected] <mailto:[email protected]>
phone-contact +14087994089
streetaddress xyxxyx
distribute
destination-profile testProfile
destination-profile testProfile format XML
no destination-profile testProfile transport-method email
destination-profile testProfile transport-method http
destination-profile testProfile http https://xyz.abc.com
destination-profile testProfile alert-group all
transport email smtp-server 64.104.140.134 port 25 use-vrf management
transport email from [email protected] <mailto:[email protected]>
enable
commit
no destination-profile testProfile transport-method email
destination-profile testProfile transport-method http
destination-profile testProfile http
DS-C9134-K9, Cisco MDS 9134 Multilayer Fabric Switch, if NPIV is enabled and the switch is
used as the NPV core switch
DS-C9124-K9, Cisco MDS 9124 Multilayer Fabric Switch, if NPIV is enabled and the switch is
used as the NPV core switch
DS-C9216i-K9, Cisco MDS 9216i Multilayer Fabric Switch
DS-X9016, Cisco MDS 9000 2-Gbps16-Port Fibre Channel Switching Module
DS-X9032, Cisco MDS 9000 2-Gbps 32-Port Fibre Channel Switching Module
DS-X9032-14K9, Cisco MDS 9000 14/2-Port Multiprotocol Services Module (MPS-14/2)
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.2(1a)
https://xyz.abc.com
Limitations and Restrictions
37