3. Associations in Z-Wave network Security Mode
i
NOTE
This parameter defines how commands are sent in specified associa-
values of parameter
tion groups: as secure or non-secure. Parameter is active only in Z-Wave
3 may be combined,
network Security Mode. It does not apply to 1st „Lifeline" group.
e.g. 1+2=3 means that
Available settings: 1 - 2nd group sent as secure
2nd & 3rd group are
sent as secure.
Default setting:
10. Key Pressed 1 time – command sent to 2nd association group
This parameter defines commands sent to devices associated in 2nd
association group after a single click.
Available settings: 0 - no action
Default setting:
11. Key Pressed 1 time – value of SWITCH ON command sent to
i
NOTE
2nd association group
Setting
parameters
This parameter defines value of SWITCh On command sent to devices
11, 13, 15, 21, 23 and
in 2nd association group after a single click.
25 to appropriate val-
Available settings: 1-255 - sent value
ue will result in:
1-99 - forcing level of
Default setting:
associated devices
255 - setting associat-
12. Key Pressed 2 times – command sent to 2nd association group
ed devices to the last
This parameter defines commands sent to devices associated in 2nd
remembered state or
association group after a double click.
turning them on
Available settings: 0 - no action
Default setting:
13. Key Pressed 2 times – value of SWITCH ON command sent to
2nd association group
This parameter defines value of SWITCh On command sent to devices
in 2nd association group after a double click.
Available settings: 1-255 - sent value
Default setting:
ADvAnCED PARAMETERS
2 - 3rd group sent as secure
4 - 4th group sent as secure
7 (all)
Parameter size:
1 [byte]
1 - SWITCh On
2 - SWITCh OFF
3 - SWITCh On/OFF – alternately
3
Parameter size:
1 [byte]
255
Parameter size:
2 [bytes]
1 - SWITCh On
2 - SWITCh OFF
3 - SWITCh On/OFF – alternately
1
Parameter size:
1 [byte]
99
Parameter size:
2 [bytes]
14. Key Pressed 3 times – command sent to 2nd association group
This parameter defines commands sent to devices associated in 2nd
association group after a triple click.
Available settings: 0 - no action
1 - SWITCh On
2 - SWITCh OFF
3 - SWITCh On/OFF – alternately
0
Default setting:
Parameter size:
15. Key Pressed 3 times – value of SWITCH ON command sent to
2nd association group
This parameter defines value of SWITCh On command sent to devices
in 2nd association group after a triple click.
Available settings: 1-255 - sent value
Default setting:
255
Parameter size:
20. Key Pressed 1 time – command sent to 3rd association group
This parameter defines commands sent to devices associated in 3rd
association group after a single click.
Available settings: 0 - no action
1 - SWITCh On
2 - SWITCh OFF
3 - SWITCh On/OFF – alternately
3
Default setting:
Parameter size:
21. Key Pressed 1 time – value of SWITCH ON command sent to
3rd association group
This parameter defines value of SWITCh On command sent to devices
in 3rd association group after a single click.
Available settings: 1-255 - sent value
Default setting:
255
Parameter size:
22. Key Pressed 2 times – command sent to 3rd association group
This parameter defines commands sent to devices associated in 3rd
association group after a double click.
Available settings: 0 - no action
1 - SWITCh On
2 - SWITCh OFF
3 - SWITCh On/OFF – alternately
Default setting:
1
Parameter size:
11
1 [byte]
2 [bytes]
1 [byte]
2 [bytes]
1 [byte]