TPS-4500IMPC Troubleshooting (continued)
TROUBLE
Touchpanel
does not
function.
Video
window on
touchpanel
has no
display.
(continued on next page)
Operations Guide - DOC. 6163
POSSIBLE CAUSE(S)
Touchpanel is not
receiving power.
Touchpanel is not
communicating to the
network.
Improper video
connection.
Incorrect video cable
used.
Incorrect video format
selection.
TPS-VID-1/2 improperly
installed in TPS-4500.
Incorrect video format
selection.
Incorrect VT Pro-e
project file loaded.
Damaged connector
pins.
Interface Module
CORRECTIVE ACTION
Confirm that power is
supplied via the power
pack or the Cresnet
connector (not both).
Use Viewport (via SIMPL
Windows or VT Pro-e) to
poll the network. Verify
network connection to the
touchpanel.
Verify proper connections
on the touchpanel and
TPS-4500IMPC.
Verify that the supplied
10-pin net/video cable
assembly is used to
connect the NET/VIDEO
port of the touchpanel to
the TPS-4500IMPC.
Check DIP switch settings
on TPS-4500IMPC.
Follow installation
procedures for
TPS-VID-1/2.
Select the proper video
input configuration in the
touchpanel configuration
SETUP MENU.
Make sure that video
window object resides in
project, re-compile, and
reload.
Inspect connector pins. If
bent, carefully re-
straighten. If broken,
contact Crestron customer
service.