The parameter is irrelevant for other modes.
Size: 1 Byte, Default Value: 1
Setting
0
slats return to previously set position only in case of the main controller operation.
slats return to previously set position in case of the main controller operation,
1
momentary switch operation, or when the limit switch is reached.
slats return to previously set position in case of the main controller operation,
2
momentary switch operation, when the limit switch is reached or after receiving the
Switch Multilevel Stop control frame
Parameter 154: Delay motor stop after reaching end switch
For blinds (parameter 151 set to 1, 2, 5 or 6) the parameter determines the time after which the
motor will be stopped after end switch contacts are closed.
For gates (parameter 151 set to 3 or 4) the parameter determines the time after which the gate
will start closing automatically if S2 contacts are opened (if set to 0, gate will not close).
Size: 2 Byte, Default Value: 10
Setting
Description
0 - 60 (0 – 60s) – time
Parameter 155: Motor operation detection
Power threshold to be interpreted as reaching a limit switch.
Size: 2 Byte, Default Value: 10
Setting
0
reaching a limit switch will not be detected
1 - 255 report interval in watt
Parameter 156: Time of up movement
This parameter determines the time needed for roller blinds to reach the top.
For modes with positioning value is set automatically during calibration, otherwise, it must be
set manually.
Size: 4 Byte, Default Value: 6000
Setting
1 - 90000 (0.01 – 900.00s, every 0.01s) – movement time