NOTE
Entering invalid value
of parameter will re-
sult in response with
Application Rejected
frame and not setting
the value.
i
NOTE
Parameter 2 values
may be combined, e.g.
1+2=3 means that in-
dications for opening/
closing and waking up
are enabled.
ADVAnCED PARAMETERS
#7: Advanced parameters
The Door/Window Sensor 2 allows to customize its operation to user's
needs. Settings are available in the FIBARO interface as simple op-
tions that may be chosen by selecting the appropriate box.
In order to configure the Door/Window Sensor 2 (using
the Home Center controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced" tab.
Wake up interval
Available settings: 0 or 3600-64800 (in seconds (1-18h), 3600s (1h)
step)
Default setting: 21600 (6h)
The Door/Window Sensor will wake up after each defined time inter-
val and always try to connect with the main controller. After a suc-
cessful communication attempt, the sensor will update configuration
parameters, associations and settings and will go into standby mode.
After failed communication attempt (e.g. lack of Z-Wave range) the
device will go into standby mode and retry to establish connection
with the main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake Up notification
frame automatically. Wake up may be still performed manually by a
clicking one of the TMP buttons (while the other button is pressed).
Longer time interval means less frequent communication and thus a
longer battery life.
1. Door/window state
This parameter allows to set in what state is door/window when the
magnet is close to the sensor.
Available settings: 0 - closed when magnet near
Default setting:
2. Visual LED indications
This parameter defines events indicated by the visual LED indicator.
Disabling events might extend battery life.
Available settings: 1 - indication of opening/closing status change
Default setting:
1 - opened when magnet near
0
Parameter size:
2 - indication of wake up (1 x click or periodical)
4 - indication of device tampering
6
Parameter size:
1 [byte]