Please check t hefollowing b efore calling forservice:
Place onecupofwater i n aglassmeasuring cupintheoven andclose thedoorsecurely.
Operate t heoven fortwominutes a tHIGH 100%..
AoDoes thelightcomeonintheoven?
YES
B. Does thecooling fanwork?
YES
(Put y ourhand overthetopventilation openings..)
C._ Does theturntable r otate when theTURNTABLE ON/OFF p adistouched a nd
TURNTABLE
ONisinthedisplay?
YES
(Itis normal fortheturntable t oturnineither d irection w hen TURNTABLE ON
is inthedisplay.)
D..Isthewaterintheovenhot?
YES
NO
NO
NO
NO
If "NO" is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker.
if both are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER. A microwave oven
should never be serviced by a "do-it-yourself"
repair person.
NOTE: If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 20 and cancel.
AC Line Voltage:
AC Power Required:
Output Power:
Frequency:
Outside Dimensions:
Cavity Dimensions:
Oven Capacity:
Cooking Uniformity:
Weight:
Hood Light:
Hood Fan:
Single phase 120V, 60Hz, AC only
1520watts
14,0 amps.
850 watts* (IEC-705-1988
Test Procedure)
2450 MHz
29 7/B"(W) x 15 3/4"(H) x 14"(D)
18 1/8"(W) x 7 3/4"(H) x 13 1/4"(D)
1..1 Cu Ft.
Turntable / Stirrer Fan System
Approx.. 57 Ibs.
2 bulbs, (30 W x 2, incandescent
light bulbs)
Horizontal discharge 237 C.FM.
Vertical discharge 230 C.FM.
* The International
Electrotechnical
Commission's
standardized
method for measuring
output wattage_ This test method is
widely recognized.
In compliance with standards set by:
FCC
- Federal Communications
Commission
Authorized.
DHHS
- Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J..
- This symbol on the nameplate means the product is listed by Underwriters
Laboratories, Inc
21