Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at HIGH 100%.
A
Does the oven light come on?
YES
NO
B
Does the cooling fan work?
YES
NO
(Put your hand over the rear ventilating
openings.)
@
Does the turntable rotate?
YES
NO
(It is normal for the turntable to turn in either direction.)
D
Is the water in the oven warm?
YES
NO
if "NO"
is the answer
to any of the above questions,
please check electrical
outlet,
fuse and/or
circuit
breaker,
if they are functioning
properly, CONTACT
YOUR NEAREST
SHARP AUTHO-
RIZED SERVICER.
A microwave oven should
never be serviced
by a "do-it-yourself"
repair person.
l,_lO"lrlE:
1. if time appearing in the display is counting down very rapidly, check Demonstration
Mode
on page 15 and cancel.
2. If the oven is set for more than 20 minutes at 80, 90 or 100 percent power level, after the
first 20 minutes the power level will automatically
adjust itself to 70 percent power to
avoid overcooking.
AC Line Voltage:
Single
phase 120V, 60Hz, AC only
AC Power Required:
1200W
10.3A
Microwave
800W*
(IEC Test Procedure)
Frequency:
2450 MHz
Outside Dimensionsi (R-230H,R-220H,R-203H)
!8W'(W)
X 107/8"(H) X !4W'(D)
(R-209H)
181is"(W) x 107&"(H) x 14W'(D)
Cavity Dimensions
:
12s/('(W)
x 77/('(H) x 131/4"(D)
Oven Capacity**:
0.8 culFt.
Cooking
Uniformity:
Turntable
system,
1 l S&'' diameter
Weight:
Approx.
25 Ib
-k
The International
Electrotechnical
Commission's
standardized
method for measuring output watt
age. This test method is widely recognized.
-k*
Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for
holding food is less.
In compliance
with standards
set by:
FCC
-
Federal Communications
Commission
Authorized.
DHHS
-
Complies
with Department
of Health and Human Services
(DHHS)
rule, CFR, Title
(_
21, Chapter
I, Subchapter
J.
-
This
symbol
on the nameplate
means
the
product
is listed
by Underwriters
Laboratories,
Inc.
17