Sharp 13K-M150 Panduan Servis - Halaman 10
Jelajahi secara online atau unduh pdf Panduan Servis untuk TV Sharp 13K-M150. Sharp 13K-M150 24 halaman.
13K-M100/150
CK13M10/15
Ë Ë Ë Ë Ë adjustment
VCO Adjustment
1. Connect a digital voltmeter between pin (44) of IC201
and ground.
2. Select a good local channel.
3. Enter the service mode. select adjustment "S10".
4. Adjust the data so that digital voltmeter should read
2.2V
5. Adjustment is complete, remove the volt-meter,
return to "normal" mode.
RF AGC Adjustment
1. Have unit receive a good local channel.
2. Enter the service mode and select service adjustment
"S08".
3. Set the data value to point where no noise or beat
appears.
4. Select another channel to confirm that no noise or
beat appears.
NOTE 1
:You will have to come out of the service
mode to select another channel.
NOTE 2
:Setting the data to "00" will pro-duce a
black raster.
Screen adjustment
1. Connect a digital voltmeter between TP852 and
TP853 on the CRT socket PWB.
Note:These test points may not be provided.
Then connect the voltmeter to both ends of R852
located near Q852 on the foil side.
2. Select a good local channel.
3. Enter the service mode and select service adjustment
"S03" and set the data value to "00" to set the color
level to minimum.(Record original data code under
adjustment "S03" before changing) You may skip this
step if you selected a B/W picture or monoscope
pattern.
4. Select service adjustment "S19" and adjust the data
value to "01" this turn off the luminance signal (Y-
mute).
5. Select service adjustment "S04" and adjust data
value to obtain 0.17 volts on the digital voltmeter.
6. Adjust the master screen cotrol untill raster darkens
to the point where raster is barely seen.
7. Adjust service adjustments "S11" red, "S12" green
and "S13" blue to obtain a good grey scale with
normal whites at low brightness level.
8. Select service adjustment "S19" and reset data to
"00".
Select service adjustment "S03" and reset data to
obtain normal color level.
9. Remove digital voltmeter.
Reset master screen cotrol to obtain normal
brightness range.
White balance adjustment
1. Have unit receive a good local channel.
2. Enter the service mode. select service adjustment
"S03" and set to "00" ( minimum color) . "S03" does
not have to be adjusted if you selected a B/W picture
or monoscope pattern.
3. Alternately adjust service adjustment data of "S14"
and "S15" untill a good grey scale with normal whites
is obtained.
4. Select service adjustment "S03" and adjust data to
obtain normal color level.
Sub-picture adjustment
1. Have unit receive a good local channel.
2. Make sure the customer picture control is set to
maximum.
3. Enter the service mode and select service adjustment
"S01".
4. Adjust the data value to achieve normal contrast
range.
Sub-Tint Adjustment
1. Have unit receive a good local channel.
2. Set customer tint control to center of it's range.
3. Enter the service mode and select service adjustment
"S02".
4. Adjust "S 02" data value to obtain normal flesh tones.
10