Sharp AR-5320 Panduan Servis - Halaman 10
Jelajahi secara online atau unduh pdf Panduan Servis untuk Semua dalam Satu Printer Sharp AR-5320. Sharp AR-5320 20 halaman. Mono laser copier/printer
Juga untuk Sharp AR-5320: Panduan Pengaturan Perangkat Lunak (16 halaman), Brosur & Spesifikasi (4 halaman)
Main
Sub
Contents
code
code
SPF jam counter display
22
22
44
34
Transfer current setting
49
01
Flash ROM program writing mode (Operating procedure)
12
Standby mode fusing fan RPM
setting
The SPF jam counter value is displayed. (Alternate display by 3 digits)When the [Interrupt] key is
pressed, the machine goes into the sub code input standby mode. When the [CA] key is pressed, the
simulation is terminated.
Used to set the transfer current for the front surface and that for the back surface. When this
simulation is executed, the current set value is displayed on the 7-seg display. Select the set value
with the zoom (Up/Down) keys and press the [START] key, and the set content is written into the
EEPROM and the machine goes into the sub code input standby mode. Press the [Mode select] key
to select each setting mode. At that time, the setup content is written into the EEPROM.
The set range is 90uA ~ 360uA in the increment of 10uA.
Display lamp
AE mode lamp
AE mode lamp & PHOTO mode lamp
AE & TEXT & PHOTO mode lamps
*
Small size paper must be Letter R (A4R) or smaller.
*
For the special size of tray, use the normal size width.
When this simulation is executed, "d" is displayed on the copy quantity display and the machine
enters the Flash ROM program writing mode. Use the writing tool on the PC to write the program.
During writing, the display is made as follows. After completion of downloading, turn OFF/ON the
power to reset.
Status
Download data reception
Data delete start
Data writing (Boot section)
Data writing (Program section)
Sum check
Completion of downloading
Error status
*
"*" in the error display indicates the error position.
00
Data receive error
02
FLASH ROM delete error
03
FLASH ROM write error (Boot section)
04
FLASH ROM write error (Program section)
05
Sum check error (Loader section)
06
Sum check error (Boot section)
When this simulation is executed, the currently set code number is displayed.
When [MODE SELECT] key is pressed, the normal setting and the high fusing temperature setting
are switched alternatively.
Enter the code number and press START key, and the number is written into the EEPROM and the
machine goes into the sub code entry standby mode.
Display lamp
AE mode lamp
Normal temperature control (190°C or less)
TEXT mode
Fusing temperature of 190°C or above
Code number
0
1
AR-5316/5320 SIMULATIONS 7-4
Details of operation
Normal size width: Front
Small size width: Front
Manual paper feed
Copy quantity display Pre-heat lamp
"d"
"d"
"d"
"d"
"d"
"OFF"
"*E"
07
Sum check error (Program section)
08
Sum check error (EEPROM section)
09
E2PROM verify error
0b
E2PROM verify error
0F
Download data length error
Setting mode
Setting
Low speed rotation
High speed rotation
Setting mode
Ready lamp
ON
OFF
ON
ON
Flash
OFF
Flash
Flash
ON
ON
OFF
OFF
OFF
OFF
Default
Low speed rotation
High speed rotation