10.0. ARMING TEST-CONTROL
With the control panel disarmed (OFF), proceed as follows:
Digit any one of the memorized
codes (example 1, 2 and 3). On
the display 3 asterisks will appear.
Press the button
The control panel emits one beep. On the
display the message on the right appears.
The writing "ON" and the LED "UNIT ON"
will flash quickly. The LED "TEST" will
light and remains so until the control panel is disarmed.
Before the writing "delay" appears, press
the button
appear and it will flash quickly.
After a few seconds the writing "delay" that
indicates a 60 seconds exit time will appear.
Press again the button
On the display a moon symbol
quickly will appear.
At the end of the exit time, the writing "delay"
will disappear and the writing "ON", the symbol
of the moon
flashing quickly will become fixed. The control
panel is armed in Test-Control Night mode.
If while arming there are zones triggered or
unbalanced not by-passed and not associated to
the Night group, or control panel has low
battery, the writing "TEST" and the symbol
of the moon
"ON" will flash slowly during the exit time.
Furthermore, the message "zone in alarm" or "battery centr." will appear.
If a few zones are by-passed or associated
to the Night group, during the exit time on
the display the message "zone by-p"
instead of "delay" will appear. To verify the
zones by-passed or associated to the
Night group, proceed as indicated on the
points 3) and 4) of the paragraph 7.0.
Violation of one or more zones provokes the appea-
rance of a flashing message on the display. Keep in
mind that only the alarm with the highest priority level
is visualized entirely on the display and remains in
memory until the control panel is newly armed.
To verify if there have been other alarm events,
access the menu by pressing the button "FORWARD".
Next to each zone that has triggered an alarm a dot
will appear that flashes slowly (see on the right).
Page 10
(NIGHT mode)
to confirm.
. The writing "TEST" will
.
that flashes
and the LED "UNIT ON" from
on the display and the LED
OFF
OK
***
ON
OK
TEST
OK
TEST
delay
OK
TEST
OK
delay
TEST
zone in alarm
zone by -p
TEST
OK
TEST
hold-up
wire
1
2
TEST
OK
3
4
"zone 3" has triggered an alarm
Digit-KD instruction manual