Digital Aquatics ReefKeeper Panduan Pengguna - Halaman 17
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Produk Perawatan Hewan Peliharaan Digital Aquatics ReefKeeper. Digital Aquatics ReefKeeper 18 halaman.
Troubleshooting
Problem
The temperature display says "Probe removed"
The temperature is inaccurate
The fuse inside the ReefKeeper has blown
6/28/2005
Solution
Ensure that your temperature probe is securely plugged into the
power controller. If it is plugged in securely, and the message is still
displayed, the probe may be faulty. Contact Digital Aquatics
technical support at [email protected]
Enter the "Setup Temp" menu. In the "Calibrate Temp" section,
adjust the temperature up or down until it displays the correct water
temperature.
To replace the fuse do the following steps:
Acquire a replacement 5mm x 20mm 15A fast fuse. P/N
•
GMA-15A (Digital Aquatics sells replacement fuses)
Unplug the ReefKeeper! (very important)
•
Remove the screws from the power controller and separate
•
the two pieces. Notice the fuse in a holder on the circuit
board.
Remove the fuse from the holder and replace it with the
•
new fuse.
Place the two box pieces back together and secure screws.
•
www.DigitalAquatics.com
APPENDIX
17