Bitstream HYPERION-402 Panduan Memulai Cepat - Halaman 5

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Beralih Bitstream HYPERION-402. Bitstream HYPERION-402 6 halaman. Managed industrial ethernet switch

Quick start manual for
M
6
ANAGEMENT
Management of the device applies HTTP and SNMP protocols, and can be performed via NMI
Ethernet port or any Ethernet ports. Additionally, access to the device parameters is possible via
SSH or RS232 console.
Note!!!: In the indicated models of switches, the firmware update from a version older than:
HYPERION-105 – v120
HYPERION-300 – v120
HYPERION-303 – v120
HYPERION-200 – v308
HYPERION-400 – v308
HYPERION-500 – v308
This will remove passwords for users existing in the configuration (including the "admin"
user).
After the upgrade, the password for each user will be blank the first time they attempt to log
in to management via WWW or CLI.
In case of the firmware is downgraded to a version lower than the one indicated above, the
users will be completely removed and a default user "admin" will be created with no
password – empty.
7
Emergency restoring access to the device
If the password is lost, there is a mechanism for generating a temporary password to access the
device via www or telnet or CLI. If you enter the password incorrectly five times via telnet or CLI or
by entering the %bitstream% command in the password field, a temporary code will be generated.
The code must be forwarded to the BitStream Support department available from 8:00 to 16:00 at
817438643 or sent by e-mail to
access the device.
If you cannot log in to the device (due to incorrectly entered configuration e.g.: vlan, etc.), you can
restore the default configuration using the "DEF" button. Holding down the "DEF" button for 5
seconds will delete the configuration without losing the IP address, and holding down the button for
more than 10 seconds will restore the configuration to factory settings.
8
CONFORMITY TO STANDARDS AND RECOMMNEDATIONS
BITSTREAM devices were designed pursuant to obligatory standards and recommendations in
respect of the range of data transmission, electromagnetic compatibility and service safety.
8.1
The device was designed pursuant to the standard EN 55022, EN-55024. BITSTREAM devices
are designated to functioning in closed premises.
Notice: This device is a class A device. In the residential environment may cause radio frequency
interference. In such cases, you can require the user to take appropriate measures.
8.2
In respect to safety of service, BITSTREAM devices were designed and tested for
operation safety along with the EN 60950 standard.
Configuration and installation of the device should be executed by authorised persons familiar with
the service manual. The producer shall not be responsible for any occurrence that could result
from usage and installation that might not conform to this manual.
REV.
1.08

Electromagnetic compatibility

Safety
SHORT USER MANUAL HYPERION-402
H-402
- www.bitstream.pl/ en/
to receive a temporary 6-hour password to
2021.03.31
5/6