Siemens SIMATIC ET 200S Manual - Halaman 7

Jelajahi secara online atau unduh pdf Manual untuk Peralatan Industri Siemens SIMATIC ET 200S. Siemens SIMATIC ET 200S 16 halaman. Distributed i/o digital electronic module 4do dc24v/2a hf
Juga untuk Siemens SIMATIC ET 200S: Panduan Operator (18 halaman), Panduan Pengguna (16 halaman), Panduan Pengguna (26 halaman), Manual (37 halaman), Manual (24 halaman), Manual Fungsi (40 halaman), Petunjuk Pengoperasian (4 halaman), Petunjuk Pengoperasian Asli (19 halaman), Petunjuk Pengoperasian Asli (20 halaman), Manual (34 halaman), Manual (14 halaman), Manual (24 halaman), Petunjuk Pengoperasian Asli (17 halaman), Petunjuk Pengoperasian Asli (19 halaman), Manual (16 halaman), Manual (28 halaman), Manual (12 halaman), Manual (32 halaman), Manual (18 halaman), Manual (12 halaman), Manual (28 halaman), Manual (22 halaman), Manual (22 halaman), Manual (36 halaman), Manual (16 halaman)

Siemens SIMATIC ET 200S Manual

Properties

1.1

Digital electronic module 2DO DC24V/2A HF (6ES7132-4BB31-0AB0)

Properties
● Digital electronic module with two outputs
● Output current 2 A per output
● Rated load voltage 24 VDC
● Diagnostics: Wire break
● Diagnostics: Short circuit
● Short-circuit protection
● Suitable for solenoid valves, DC contactors, and indicator lights
● Supports isochronous operation
● Extended temperature range from 0 to 55 °C with vertical installation
Peculiarity
When you connect the 24 VDC rated load voltage to the power module by means of a
mechanical contact, depending on the circuit the digital outputs carry the "1" signal for
approximately 50 µs. You need to take this into account if you connect the module to fast
counters.
General terminal assignment
Note
Terminals 4, 8, A4, A8, A3 and A7 are only available at specified terminal modules.
Terminal
Assignment Terminal
1
DO
0
2
L+
3
M
4
n.c.
A4
AUX1
A3
AUX1
Digital electronic module 2DO DC24V/2A HF (6ES7132-4BB31-0AB0)
Manual, 04/2007, A5E01077255-01
Terminal assignment for 2DO 24 VDC/2 A HF (6ES7132-4BB31-0AA0)
Assignment
5
DO
1
6
L+
7
M
8
n.c.
A8
AUX1
A7
AUX1
DO
: Output signal, Channel n
n
L+: Rated load voltage 24 VDC
M: Ground
n.c.: Not connected (max. 30 V DC can be connected)
AUX1: Protective-conductor terminal or potential bus (freely usable
up to 230 VAC)
Notes
1