Juga untuk Siemens SIMATIC ET 200SP: Manual (40 halaman), Panduan Pengguna (21 halaman), Manual (48 halaman), Manual (30 halaman), Manual (34 halaman), Informasi Produk (38 halaman), Manual (37 halaman), Manual (36 halaman), Manual (44 halaman), Manual (31 halaman), Manual (35 halaman), Manual (23 halaman), Panduan Konfigurasi (20 halaman), Manual (34 halaman), Manual (29 halaman), Manual (33 halaman), Manual (31 halaman), Panduan Pengguna (32 halaman), Manual (31 halaman), Manual (28 halaman), Manual (41 halaman), Manual (32 halaman), Manual (49 halaman), Manual (24 halaman), Manual (34 halaman), Manual (41 halaman), Manual (30 halaman), Manual (31 halaman), Manual (27 halaman), Manual (24 halaman), Manual (24 halaman), Manual (25 halaman), Manual (49 halaman), Manual (40 halaman), Manual (38 halaman), Manual (39 halaman), Informasi Produk (24 halaman), Manual (32 halaman), Informasi Produk (10 halaman), Panduan Peralatan (43 halaman), Manual (33 halaman), Panduan Peralatan (44 halaman), Petunjuk Pengoperasian Asli (6 halaman), Manual (35 halaman), Manual (28 halaman), Panduan Peralatan (32 halaman), Manual (50 halaman), Manual (30 halaman), Manual (26 halaman), Manual (28 halaman), Manual (34 halaman), Manual (44 halaman), Manual (33 halaman), Panduan Peralatan (42 halaman), Manual Petunjuk Asli (16 halaman)

Siemens SIMATIC ET 200SP Manual

Parameter data record

A.1

Dependencies when configuring with GSD file

When configuring the module with a GSD file, remember that the settings of some
parameters are dependent on each other.
Configuring with a PROFINET GSD file
The table lists the properties and their dependencies on the measurement type and
measuring range for PROFINET.
Measurement type
Measuring range
Deactivated
Voltage
±5 V
±10 V
1 V to 5 V
0 V to 10 V
x = Property is allowed, - = Property is not allowed, * = Property is not relevant
Configuring with a PROFIBUS GSD file
The table lists the properties and their dependencies on the measurement type and
measuring range for PROFIBUS.
Measurement type
Measuring range
Deactivated
Voltage
±5 V
±10 V
1 V to 5 V
0 V to 10 V
x = Property is allowed, - = Property is not allowed, * = Property is not relevant
Analog input module AI 2xU ST (6ES7134-6FB00-0BA1)
Manual, 12/2015, A5E36104728-AA
No supply voltage
Short-circuit to
L+
ground
*
*
x
-
x
-
x
x
x
-
No supply voltage
Short-circuit to
L+
ground
*
*
x
-
x
-
x
x
x
-
Diagnostics
Overflow
*
x
x
x
x
Diagnostics
Overflow
*
x
x
x
x
A
Underflow
*
x
x
x
x
Underflow
*
x
x
x
x
27