Siemens SIMATIC NET RUGGEDCOM i801 Panduan Instalasi - Halaman 25

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Peralatan Industri Siemens SIMATIC NET RUGGEDCOM i801. Siemens SIMATIC NET RUGGEDCOM i801 38 halaman. Rugged ethernet switches
Juga untuk Siemens SIMATIC NET RUGGEDCOM i801: Panduan Instalasi (36 halaman)

Siemens SIMATIC NET RUGGEDCOM i801 Panduan Instalasi
Communication Ports
4.1 Copper Ethernet Ports
Electric shock hazard – risk of serious personal injury and/or equipment
interference
If shielded cables are used, make sure the shielded cables do not form a ground loop
via the shield wire and the RJ45 receptacles at either end. Ground loops can cause
excessive noise and interference, but more importantly, create a potential shock
hazard that can result in serious injury.
Each port features a Speed and Link LED that indicates the state of the port.
Speed
Link
The following is the pin-out for the RJ45 male connectors:
8
Figure 4.2
For specifications on the available copper Ethernet ports, refer to
Port Specifications (Page
16
WARNING
LED
Yellow
Off
Yellow (Solid)
Yellow (Blinking)
Off
1
RJ45 Ethernet Port Pin Configuration
Pin
10/100TX
1
RX+
2
RX-
3
TX+
4
Reserved (Do Not Connect)
5
Reserved (Do Not Connect)
6
TX-
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
State
The port is operating at maximum speed
The port is not operating at maximum speed
Link established
Link activity
No link detected
Name
1000TX/SX/LX
BI_DA+
BI_DB+
BI_DC+
BI_DD+
19)".
Description
Receive Data+ or Bi-
Directional Pair A+
BI_DA-
Receive Data- or Bi-
Directional Pair A-
Transmit Data+ or Bi-
Directional Pair B+
Transmit Data+ or Bi-
Directional Pair C+
BI_DC-
Receive Data- or Bi-
Directional Pair C-
BI_DB-
Transmit Data- or Bi-
Directional Pair B-
Receive Data- or Bi-
Directional Pair D+
BI_DD-
Receive Data- or Bi-
Directional Pair D-
"Copper Ethernet
Installation Manual, 01/2021, C79000-G8976-1003-06
Description
RUGGEDCOM i801