Siemens SIMATIC RTLS4040T Panduan Petunjuk Pengoperasian - Halaman 15
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Peralatan Industri Siemens SIMATIC RTLS4040T. Siemens SIMATIC RTLS4040T 21 halaman. Localization systems
Juga untuk Siemens SIMATIC RTLS4040T: Panduan Petunjuk Pengoperasian (23 halaman)
3.4
Charging instructions
Note
Fully charge the device upon receipt.
Place the charging station in a place with cool ambient temperature.
The temperature of the device and the ambient temperature must not exceed 40 °C for the
device to be charged. The higher the temperature, the longer it takes to charge the device.
If the device exceeds 55 °C during charging (see Status LED), remove the device from the
charging station. Allow the device to cool down and try charging it again. If the device
becomes too hot again, remove the device from the charging station and contact customer
service.
The battery has a natural self-discharge. When stored in a state not fully charged, the device
is discharged after approximately 6 months and must be recharged. If the device is
completely discharged, the integrated battery may be damaged. This device can then no
longer be charged.
Read also the descriptions of the operating states of the device in section "LED operation
display & function button (Page 10)"
SIMATIC RTLS4040T
Operating Instructions, 12/2020, C79000-G8976-C596-01
Installation & operation
3.4 Charging instructions
15