WARNING
To be observed when using in hazardous areas:
- The decree governing electrical systems in hazardous rooms (according to the
valid national standard, in Germany ElexV §§ 9,15).
- The conditions for installing electrical systems in hazardous areas DIN EN
60079-14 (VDE0165) or DIN EN1127-1.
- The specifications of the EC certificate of conformity.
- All work on electrical circuits for systems where there is a risk of explosion
must be performed by qualified personnel.
5.4

Electromagnetic Compatibility

To maintain EMC, e.g.
- an EMC-compatible laying of cables (also inside cabinets) must be
observed .
- the signal cable must be laid separately from cables with voltages > 60 V or
high currents.
- the vicinity of large electrical installations must be avoided.
- shielded cables must be used.
- proper grounding must be observed.
SIWAREX R Load Cells Operating Manual
A5E00159640
Technical Data
26