3.2

Layout and function

3.2.1

Design and principle of operation of the mounting plates

Design
The mounting plates comprise the following components:
● Upper mounting plate ①
● Lower mounting plate ⑥
Together with the load cell and the pressure piece set the mounting plates represent a self-
centering bearing unit.
Figure 3-3
CP-S SA
Operating Instructions, 04/2009, A5E02522341B
Upper mounting plate
Upper pressure piece, not included in the scope of delivery
Load cell, not included in the scope of delivery
Pin in lower pressure piece: Prevents the load cell from twisting
Lower twistproof pressure piece, not included in the scope of delivery
Lower mounting plate
Exploded view: Mounting plates with pressure piece set and installed load cell
Description
3.2 Layout and function
11