Siemens CM676G0.6 Panduan Pengguna dan Petunjuk Instalasi - Halaman 42

Jelajahi secara online atau unduh pdf Panduan Pengguna dan Petunjuk Instalasi untuk Oven Siemens CM676G0.6. Siemens CM676G0.6 48 halaman.

Siemens CM676G0.6 Panduan Pengguna dan Petunjuk Instalasi
en Installation instructions
28.3 Installation below a worktop
Observe the installation dimensions and the installation
instructions when installing below a worktop.
28.4 Installation underneath a hob
If the appliance is installed under a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
Hob type
Induction hob
Full-surface induction hob
Gas hob
Electric hob
28.5 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
42
a raised in mm
42
52
32
32
¡ To ventilate the appliance, the intermediate floor
must have a ventilation cut-out.
¡ The worktop must be secured to the built-in unit.
¡ Observe any available installation instructions for the
hob.
The minimum worktop thickness
required minimum clearance
a flush in mm
43
53
43
35
¡ To ventilate the appliance, the intermediate floors
must have a ventilation cut-out.
¡ In order to ensure sufficient ventilation of the appli-
ance, there must be a ventilation opening of at least.
200 cm² in the base area. To do this, trim the base
​ ⁠ a is based on the
​ ⁠ .
b in mm
5
5
5
2