Siemens CM836GP.6 Panduan Pengguna dan Petunjuk Instalasi - Halaman 44

Jelajahi secara online atau unduh pdf Panduan Pengguna dan Petunjuk Instalasi untuk Oven Siemens CM836GP.6. Siemens CM836GP.6 48 halaman.

Siemens CM836GP.6 Panduan Pengguna dan Petunjuk Instalasi
en Installation instructions
27.5 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
¡ To ventilate the appliance, the intermediate floors
must have a ventilation cut-out.
¡ In order to ensure sufficient ventilation of the appli-
ance, there must be a ventilation opening of at least.
200 cm² in the base area. To do this, trim the base
panel or fit a ventilation grille. Ensure that the air ex-
change is guaranteed in accordance with the dia-
gram.
¡ If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡ Only fit the appliance up to a height which allows
accessories to be easily removed.
27.6 Corner installation
Observe the installation dimensions and the installation
instructions when installing in a corner.
44
¡ To ensure that the appliance door can be opened,
you must take the minimum dimensions into consid-
eration when installing in a corner. The dimension
is dependent on the thickness of the unit front and
the handle.
27.7 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡ The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡ The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to local regulations.
¡ The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡ The appliance must only be connected using the
power cable provided.
¡ The power cable must be plugged in at the rear of
the appliance until you hear a clicking sound. A 3 m
power cable can be obtained from the after-sales
service.
¡ The power cable must only be replaced with a cable
from the original manufacturer. This is available from
after-sales service.
¡ Contact protection must be ensured during the in-
stallation.
Electrically connect the appliance with the
protective contact plug
Note: The appliance must only be connected to a pro-
tective contact socket that has been correctly installed.
Insert the plug into the protective contact socket.
When the appliance is installed, the mains plug of
the power cord must be freely accessible. If free ac-
cess to the mains plug is impossible, an all-pole
isolating switch must be integrated into the perman-
ent electrical installation in accordance with the in-
stallation regulations.
Electrically connecting an appliance without a
protective contact plug
Note: Only a licensed professional may connect the ap-
pliance. Damage caused by incorrect connection is not
covered under the warranty.
An all-pole isolating switch must be integrated into the
permanent electrical installation according to the install-
ation regulations.
Identify the phase and neutral conductors in the
1.
socket.
The appliance may be damaged if it is not connec-
ted correctly.
Connect the hob in accordance with the connection
2.
diagram.
See the rating plate for the voltage.
Connect the wires of the mains power cable accord-
3.
ing to the colour coding:
Green/yellow = Protective conductor
Blue = Neutral conductor
Brown = Phase (external conductor)