Technical data and dimensions
10.1 Technical data
Thread G¾, ¾ NPT
Thread G1, 1 NPT
Hygienic adapter
Surface quality
Measurement accuracy
Hysteresis
Switching delay
Ambient conditions
Ambient temperature on the
housing
Storage and transport
temperature
Relative humidity
Mechanical environmental conditions
Sinusoidal vibrations
Impacts
Impact resistance
Process conditions
Process pressure
Process temperature
Vapour stratification up to 1 h
Dielectric constant
Indication (NE 107)
360° status indication (LED)
Green
Yellow
Red
Output variable - Transistor output
Output
Load current
Voltage loss
28
75 Nm (55 lbf ft)
100 Nm (73 lbf ft)
20 Nm (15 lbf ft)
Ra < 0.76 µm (3.00-5 in)
approx. 1 mm (0.04 in)
approx. 500 ms (on/off)
-40 ... +70 °C (-40 ... +158 °F)
-40 ... +80 °C (-40 ... +176 °F)
20 ... 85 %
4M8 (5 g) at 4 ... 200 Hz according to EN 60068-2-6 (vibration with
resonance)
50 g, 2.3 ms according to EN 60068-2-27 (mechanical shock)
IK05 acc. to IEC 62262
-1 ... 25 bar/-100 ... 2500 kPa (-14.5 ... 363 psig)
-20 ... +100 °C (-4 ... +212 °F)
+135 °C (+275 F)
≥ 2.0
Power supply on - Output 1 open
Power supply on - Output 1 closed
Voltage supply on - failure/simulation
Transistor (PNP/NPN)
max. 250 mA (output, permanently short-circuit proof)
< 3 V
SITRANS LCS050
Operating Instructions, 02/2021,
A5E50859888