Installation continued
Connection
Electrical:
An electrical 10 amp socket needs to be within 1 m of the
hotplate to allow electrical connection. The socket must remain
accessible after installation of the appliance.
Important note:
This appliance is connected to the mains (240 VAC) by means
of the connecting lead which must be fixed to the kitchen unit
to prevent it from coming into contact with hot parts of the hob
(or an oven installed underneath) and remain accessible after
installation of the cooktop.
sure that the lead cannot come into contact with hot parts
of the hob.
Important: This appliance must be earthed. When connecting
the cooktop ensure that the earth wire is connected first and
that all wires are connected to the correct terminals.
Gas:
During the planning stage, consider the position of supply
connections.
The hob must be connected to the gas supply with upstream
connection of an isolation valve in accordance with the respec-
tively valid regulations. We recommend that the isolation valve
be fitted prior to the cooktop to enable isolation of cooktop
from gas supply. The valve must be easily accessible at all
times.
To find out the factory set gas type, see bottom of cooktop next
to gas connection.
Remove plastic cap from gas supply line prior to installation.
Fit regulator (N.G.) or a test point (Universal LPG) directly
to the
Direction of gas flow is indicated on the rear of the regulator.
For position of the inlet connection refer Fig.1-1a.
Use pipe compound or thread sealant, properly theaded pipes
and careful assembly procedure so that there is no cross
threading, etc., which might cause damage or leakage.
Make sure that all connections peformed are free of leakage.
The manufacture does not accept any liability for leakage on
connections performed by the installer or if the L-tube is moved
or twisted.
Pressure
test point
9
When making this connection make
1 /
R
" connection as per Fig. 5. and Fig. 6.
2
Universal LPG connection
Natural gas connection
1
Gasket
R
/
"
2
1
R
/
"
2
5
6
Wok burner operation
Gasket
Pressure
test point.
The wok control has 4 settings.
Largest flame =The outer and inner burners are both
operating on high flame.
Large flame = The outer burner burns low and the
inner burner burns high.
Small flame = Only the inner burner burns high.
Smallest flame = Only the inner burner burns low.
For ongoing cooking a variable setting between the flame
sizes can be used.
14