ActronAir QUE QZB-100 Instalasi dan Panduan Pengguna - Halaman 4

Jelajahi secara online atau unduh pdf Instalasi dan Panduan Pengguna untuk Pengontrol ActronAir QUE QZB-100. ActronAir QUE QZB-100 13 halaman.
Juga untuk ActronAir QUE QZB-100: Instalasi dan Panduan Pengguna (13 halaman)

ActronAir QUE QZB-100 Instalasi dan Panduan Pengguna
Wall Mount Dimensions
43mm
CTR
Zone Controller Mount
H x W = 81.1mm x 65.3mm
Zone Device Combination Options
Option 1
Option 2
Option 3
Zone controller
Remote sensor
Zone controller
only
only
+ remote sensor
(averaging)
Dining
Dining
24.0 C
o
24.0 C
o
Zone OFF
Zone OFF
AC OFF
AC OFF
OFF
OFF
NOTE: Following options are not allowed: (1) Master Controller + Zone Controller or (2) Two zone controller
6
43mm
CTR
Remote Sensor Mount
H x W = 51.3mm x 63.3mm
Option 4
2 remote sensor
Master controller
(averaging)
+ remote sensor
+
+
Wall Installation
Run a green Cat5E cable through a 25mm diameter hole in the wall.
Plug in RJ45 connector and secure the controller in the control bracket.
Available ActronAir Cat5E green cable:
P.N. 4070-027 7 metres
P.N. 4070-031 20 metres
1
To 12VDC Power Source
Option 5
Wall mates (x2)
Plyboard wall
+
NOTE:
Use provided wall plugs (x2) in lieu of wall mates if applicable. Use the
provided screws. Wall mates or wall plugs must be totally flush to the wall.
Hole for cable MUST not be MORE THAN than 25mm diameter.
Zone controller or
2
remote sensor
Screw (x2)
Control bracket
7