Installer fitting instructions.... continued
Setting obstruction force (see figure 3)
This facility is provided to stop the door when it encounters an obstruction or jambs.
For each installation the obstruction force setting must be adjusted. Failure to do
this correctly may cause serious injury or damage, and will void any warranty.
• Screwdriver adjustments are made on the blue control panel located on the
control board
• Use the remote control (or optional fixed push button) to operate the door
when setting these controls
• To test the obstruction force, press the remote control (or optional fixed push
button) to close the door
• Obstruct the door by holding it at the bottom, this will cause it to stop and
reverse
• For the obstruction sensing to detect an object in the door way, some force will
be applied to the object which may suffer damage or injury to the object,
person and/or door.
• Set this for the required force with the close force adjusting control
• The open force is set by holding the door when it is opening; this time the door
will just stop
• Periodic maintenance is required to maintain optimum performance. The
obstruction force may need to be re-adjusted in the future as the door ages.
Auto-Close (see figure 3)
This feature allows the door to close automatically 45 seconds after it opens
Photo Electric Safety Beams must be fitted to use this feature as a practical
necessity and to conform to required regulations. A safety circuit is provided for
this purpose see photoelectric beam section on this page.
This option is selected by moving the link on plug J1 located at the middle top of the
control board
J1 has 3 pins the off position links the centre pin to OFF. The on position links the
centre position to ON. (Normal factory setting is OFF)
Manual push button (see figure 3)
If required a normally open push button can be connected to the screw terminals
CO and BT located at the centre bottom of the control board on terminal block X4
Photoelectric beam (see figure 3)
• Use screw terminal +24 and 0V for the detector 24volts power
• Remove the link from CO & IR and connect the photoelectric detector switch
to these terminals. This switch must be closed when operating normally and
should open when the beam is broken
• The screw terminals are located at the bottom on the controller board on
terminal block X4