CabanaCoast CB-1224 Panduan Pengguna - Halaman 12
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Perapian Luar Ruangan CabanaCoast CB-1224. CabanaCoast CB-1224 19 halaman. Fire natural gas

Gas Setup for Natural Gas (Conversion kit required)
1.
With burner in place in CabanaCoast® fire pit ta-
ble or other installation location and proper
sized orifice inserted in burner neck (see chart
on p.4 for natural gas orifice sizing), adjust air
shutter to a closed position (as shown at right,
no light visible through the shutter) by loosening
the small screw on the air shutter and rotating it
to a closed position and re-tightening screw.
2.
Locate the included metal flex-line hose and
thread one end onto orifice and tighten securely
with two wrenches.
At this point if you are connected to natural gas
3.
using a valve assembly such as The CabanaCoast® valve
kit, proceed to step 3a.
3a. Attach the free end of flex hose to the top
outgoing) flare fitting of control valve and tight-
enfully with two wrenches. Plumb incoming nat-
ural gas to the incoming side of the valve using a
3/8" flare nut. It is strongly recommended that a
manual shutoff valve is placed in the natural gas
line before it reaches the fire pit's control valve.
12
CabanaCoast® fire pit Control panel kit
CHECK ENTIRE SYSTEM FOR LEAKS BEFORE OPERATING