Cisco Aironet 1530 Panduan Memulai - Halaman 16
Jelajahi secara online atau unduh pdf Panduan Memulai untuk Titik Akses Nirkabel Cisco Aironet 1530. Cisco Aironet 1530 41 halaman. Outdoor access points
Power Injectors
The 1530 Series Access Points support the following power injectors:
• AIR-PWRINJ1500-2= — 100-240 VAC input, indoor use only
• AIR-PWRINJ-30= — 100-240 VAC input, indoor use only
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Statement 1023
When the access point is installed outdoors or in a wet or damp location, the AC branch
Caution
circuit that is powering the access point should be provided with ground fault protection
(GFCI), as required by Article 210 of the National Electrical Code (NEC).
Ethernet (PoE) Ports
The access point supports an Ethernet uplink port (PoE-In). The access point Ethernet uplink port uses
an RJ-45 connector (with weatherproofing) to link the access point to the 10BASE-T, 100BASE-T or
1000BASE-T network. The Ethernet cable is used to send and receive Ethernet data and to optionally
supply inline 56-VDC power from the power injector.
The access point senses the Ethernet and power signals and automatically switches internal
Tip
circuitry to match the cable connections.
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Statement 1023
The Ethernet cable must be a shielded outdoor rated Category 5e (CAT5e) or better cable. The access
point senses the Ethernet and power signals and automatically switches internal circuitry to match the
cable connections.
16