Step 5
Repeat Step 2 through Step 4 on the second DC power supply.
Wiring the DC-Input Power Source
The color coding of the DC-input power supply leads depends on the color coding of the DC power source at your site.
Note
Typically, green or green/yellow is used for ground (GND) on the power supply. Negative –48V black is on negative (–)
terminal and red is used for RTN on the positive (+) terminal. Make certain the lead color coding you choose for the
DC-input power supply matches lead color coding used at the DC power source.
Step 1
Make sure the power switch circuit breaker is in the Off (O) position.
Locate and remove the plastic cover from the terminal block.
Step 2
See
Figure 17
if you are using the ASR1006-PWR-DC power supply.
Figure 17
DC Power Supply Terminal Block Plastic Cover (ASR1006-PWR-DC)
DC power supply terminal block negative stud
1
DC power supply terminal block positive stud
2
See
Figure 17
if you are using the ASR1013/06-PWR-DC power supply.
1
2
5 5
-4 8 /- 6 0 V
4 0 A
T h is u n it
m ig h t h a v
e m o re th
a n o n e p o
w e r s u p p
ly c o n n e c
ti o n . A ll c o
4
3
Terminal block slotted keyed area
3
DC power supply terminal block plastic cover
4
n n e c ti o n s
m u s t b e re
m o v