4 - ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)

Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with
foamed polyethylene (min. thickness 8mm). For tubing dimensions, tubing length and elevation difference limits, see
installation manual of outdoor unit.
MODEL
ADIAS19
AWIB-CS13
PVC pipe for condensate drain pipe (ø int.18mm) in length suitable to let the condensate flow into the outside drainage.
Anti-freeze oil for flare connections (about 30g.).
Electric wire: use insulated copper wires of size and length as shown in the paragraph "WIRING DIAGRAMS" (Outdoor
unit).

5 - OPERATING LIMITS

■ Cooling Maximum conditions
Outdoor temperature :
Room temperature :
■ Cooling Minimum conditions
Outdoor temperature :
Room temperature :

6 - ACCESSORIES SUPPLIED WITH THE UNIT

The following accessories are supplied with the unit:
• Remote control unit.
• Batteries for remote control unit.
• Receiver assembly.

7 - TOOLS REQUIRED FOR INSTALLATION (NOT SUPPLIED)

1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
NARROW TUBE
OUTER DIAMETER
MIN. THICKNESS
6,35 mm
6,35 mm
43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
7. Hacksaw
8. Core bits ø 8
9. Hammer
10. Drill
11. Tube cutter
OUTER DIAMETER
0,8 mm
9,52 mm
0,8 mm
12,7 mm
■ Heating Maximum conditions
Outdoor temperature :
Room temperature :
■ Heating Minimum conditions
Outdoor temperature :
Room temperature :
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
5
LARGE TUBE
MIN. THICKNESS
0,8 mm
0,8 mm
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
EN