MATRIX SYSTEM OVERVIEW

Matrix System

The Matrix Switch is a high performance system used to switch
audio/video frequencies. It will cross switch multiple input/output
audio/video signals through independent Y/Pb/Pr component and
audio input/output terminals. Each Y/Pb/Pr component signal and
audio signal is transmitted separately and switched separately,
thereby minimizing signal attenuation and ensuring high definition
graphics and high fidelity audio signal output.
The primary use is; TV broadcasting projects, multi-media conference
halls, large display projects, TV teaching, and command control
centers. It features power interruption protection during power surge,
LCD display, and synchronous and separate audio/video switching
functions. The RS-232 and RS-485 communication ports enable
convenient communication with remote control equipment. This
manual describes the SW404HD and SW808HD models.

Matrix System Models

Model
Video
Video
Input Port
Output Port
SW404HD
4
4
SW808HD
8
8

Matrix System Packing

When unpacking, ensure the following items are found:
• One SW XXX HD Matrix
• One RS-232 cable
• One power cable
• One testing and application CD
• One user manual
• Two green terminals

Matrix Host Installation

The SW XXX HD Matrix should be placed on a sturdy desk or installed
on a 19-in rack
T
e
h c
n
c i
l a
P
a
a r
m
e
e t
s r
Audio
RS-485
RS-232
Audio
Input Port
Connector
Connector
Output Port
4
4
8
8
Address Byte (Command Type A and B)
7
6
5
BT
X
CRC
Broadcast Reserved
CRC
BT: Broadcast
0: Instruction for one machine with matching Machine ID
1: Instruction for all machines
If BT = 1, machine will not return a response packet.
If BT = 0, machine must respond
CRC: CRC-8
0: Host (computer) does not append a CRC byte at end of
command packet
1: Host appends a CRC byte to end of command packet
Instruction Code Byte (Command Type A and B)
7
6
5
VAR
X
I5
Variable
Reserved Instruction Code (6-bit command)
Length
VAR: Variable Length
0: The command packet is 4 bytes with Output and
Input bytes
1: The command packet is variable length and
contains a length byte indicating the number of
Output and Input bytes
Length Byte (Command Type B only)
L7
L6
L5
Number of Output and Input Bytes to follow not including CRC
Output Byte (Command Type A and B)
O7
O6
O5
Refer to Command Table
Input Byte (Command Type A and B)
I7
I6
I5
Refer to Command Table
CRC (Command Type A and B)
C7
C6
C5
CRC-8 calculated from all bytes in packet.
Appended if CRC bit set in Instruction code
4
3
2
1
M4
M3
M3
M1
Machine ID (5-bit address)
4
3
2
I4
I3
I2
L4
L3
L2
L1
O4
O3
O2
O1
I4
I3
I2
I1
C4
C3
C2
C1
0
M0
1
0
I1
I0
L0
O0
I0
C0