Sony BRC-X401 Daftar Perintah - Halaman 8

Jelajahi secara online atau unduh pdf Daftar Perintah untuk Camcorder Sony BRC-X401. Sony BRC-X401 41 halaman. Srt introduction
Juga untuk Sony BRC-X401: Manual (15 halaman), Panduan Teknis (15 halaman)

Sony BRC-X401 Daftar Perintah

VISCA Camera-Issued Messages

ACK/Completion Messages
Command
ACK
Completion
y = Device address + 8 (Locked to "y = 9" for VISCA over IP.)
Error Messages
Command
Syntax Error
Command Buffer Full
Command Canceled
No Socket
Command Not
Executable
y = Device address + 8 (Locked to "y = 9" for VISCA over IP.)
Network Change Message
Command
Network Change*
* Not available for VISCA over IP.
y = Device address + 8
Command Message
y0 4z FF
(z: Socket No.)
y0 5z FF
(z: Socket No.)
Command Message
y0 60 02 FF
y0 60 03 FF
y0 6z 04 FF
(z: Socket No.)
y0 6z 05 FF
(z: Socket No.)
y0 6z 41 FF
(z: Socket No.)
Command Message
y0 38 FF
Comments
Returned when the command is accepted.
Returned when the command has been executed.
Comments
Returned when the command format is different or when a
command with illegal command parameters is received.
Could not accept a command that is received while two commands
are currently being executed (two sockets have been used).
Returned when a command which is being executed in a socket
specified by the cancel command is cancelled. The completion
message for the command is not returned.
Returned when no command is executed in a socket specified by
the cancel command, or when an invalid socket number is
specified.
Returned when a command cannot be executed due to current
conditions. For example, when a command for controlling the
manual focus is received during the auto focus mode.
Comments
Issued when power is supplied to the camera.
8