DigiTech XC0416 Panduan Pengguna - Halaman 3
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Stasiun Cuaca DigiTech XC0416. DigiTech XC0416 4 halaman. Temperature/humidity weather station with 7” colour display
TEMPERATURE AND HUMIDITY TREND
The temperature and humidity trend indicator shows the trends of changes in the
forthcoming few minutes. Arrows indicate a rising, steady or falling trend.
Arrow indicator
Trend
Rising
COMFORT INDICATION
The comfort indication is a pictorial indication based on indoor air temperature
and humidity in an attempt to determine comfort level.
Too cold
Note:
- Comfort indication can vary under the same temperature, depending on the humidity.
- There is no comfort Indication when temperature is below 0°C(32°F) or over 60°C
(140°F).
THE SNOW ICON
When the outdoor temperature is 3°C or below, the
flashing snow icon will appear in outdoor section.
WEATHER FORECAST
The device contains sensitive pressure sensor built-in with sophisticated and proven
software that predicts weather for the next 12 ~ 24 hours within a 30 to 50 km (19-31
miles) radius.
Sunny / Clear
Rainy
Note:
1.
The weather forecast is meant for the next 12 - 24 hours, it may not necessarily
reflect the current situation.
2.
The weather icon will flash on display when the rainstorm comes.
3.
The SNOWY weather forecast is not based on the atmospheric pressure, but based
on the outdoor temperature. When the outdoor temperature is below -3°C (26°F),
the SNOWY weather indicator will be displayed on the LCD.
BAROMETRIC/ATMOSPHERIC PRESSURE
TO SELECT THE DISPLAY MODE
Press and hold the [ BARO ] key for 2 seconds to toggle between:
ABSOLUTE the absolute atmospheric pressure of your location
RELATIVE
the relative atmospheric pressure based on the sea
TO SET RELATIVE ATMOSPHERIC PRESSURE VALUE
1.
Press and hold the [ BARO ] key for 2 seconds until ABSOLUTE or RELATIVE icon
flashes.
2.
Press [ CHANNEL / + ] key or [ MEM / - ] key to switch to RELATIVE mode.
Press the [ BARO ] key once again until the RELATIVE atmospheric pressure digit
3.
flashes.
4.
Press [ CHANNEL / + ] key or [ MEM / - ] key to change the value.
5.
Press the [ BARO ] key to save and exit the setting mode.
Note:
- The default relative atmospheric pressure value is 1013 hPa (29.92 inHg), which
refers to the average atmospheric pressure.
- When you change the relative atmospheric pressure value, the weather indicators will
change along with it.
- The relative atmospheric pressure is based on the sea level, but it will change with the
absolute atmospheric pressure change.
TO SELECT THE MEASUREMENT UNIT FOR THE BAROMETER
1.
Press the [ BARO ] key to enter unit setting mode.
2.
Use the [ BARO ] key to change the unit between inHg / mmHg / hPa.
3.
Press the [ BARO ] key to confirm.
HEAT INDEX / DEW POINT
TO VIEW HEAT INDEX
Press the [ INDEX ] key repeatedly to show HEAT INDEX
value.
Steady
Comfortable
Too hot
Slightly Cloudy
Cloudy
Snowy
Note:
Heat index is only calculated when temperature is 27° C (80° F) or above, and based
solely from the temperature and humidity measured from the outdoor wireless sensors.
TO VIEW DEW POINT
Press the [ INDEX ] key repeatedly to show DEW POINT
Falling
value.
Note:
The dew point is the temperature below which the water vapor in air at constant
barometric pressure condenses into liquid water at the same rate at which it evaporates.
The condensed water is called dew when it forms on a solid surface. The dew point
temperature is calculated from the outdoor temperature and humidity measured at the
outdoor wireless sensors.
HISTORY DATA (WEATHER RECORDS IN THE PAST 24 HOURS)
The main unit will record past 24 hours weather data automatically that included past
indoor and outdoor temperature & humidity, Baro, and Dew point / heat index records.
Press the [ HISTORY ] key to check past 1 hour history records.
1.
2.
Press [ HISTORY ] key repeatedly to show past 2, 3, 4 , 5.......24 history weather
records.
MAX/MIN RECORD
The main unit preserves the MAX/MIN weather data records since the last manual reset.
1.
In normal mode, press [ MEM / - ] key once to show the current channel's maximum
temperature.
2.
Press [ MEM / - ] key repeatedly to show the MAX/MIN reading in this order: current
channel's maximum temperature
current channel's maximum humidity
indoor maximum temperature
maximum humidity
minimum baro reading
3.
When the MAX/MIN records are shown, the display will return to normal mode after
leaving the unit for 6 seconds.
4.
To erase the MAX/MIN records of indoor or current channel, press and hold [ MEM
/ - ] key for 2 seconds when the unit is displaying MAX/MIN records.
ALERT SETTING AND DISPLAY
The unit can setup temperature HI/LO alert for indoor and up to 8 outdoor
channels.
In normal mode, press and hold [ ALERT ] key for 2 seconds to enter alert setting
1.
mode and the "IN" icon will flash. Press [ CHANNEL / + ] or [ MEM / - ] key again to
choose outdoor channel.
2.
Press [ ALERT ] key to switch between channel, temperature HI, temperature LO,
humidity HI and humidity LO alert setting.
3.
Press [ CHANNEL / + ] or [ MEM / - ] key to modify the value by 0.1 °C/°F for
temperature or 1% for humidity, you can also press and hold to quick adjust the
value.
4.
When setting temperature Hi or Lo value, press [ ALARM ] key to toggle the alarm
on/off of the regarding HI / LO alert.
5.
When finished, press and hold [ ALERT ] key for 2 seconds or without pressing keys
for 60 seconds to return normal mode.
High temperature alert on
Note:
- You cannot enter conflicting HI / LO values in the setting. For example, if the HI
temperature alert value is 40°C, you cannot enter more than 39.9°C for the LO alert,
and so forth.
- When the alert is triggered, the alarm will sound and the alarm icon on the display will
flash. Press [ ALARM / SNOOZE ], [ ALARM ] or [ ALERT ] key to stop the alarm
sound. If you ignore the alarm, it will stop after 2 minutes.
- When auto-cycle mode, if any alarm is triggered the display will switch to the regarding
channel. You can press [ ALARM / SNOOZE ], [ ALARM ] or [ ALERT ] key or leave
the unit for 2 minutes to stop the alarm. The display will return to auto-cycle mode
afterwards.
current channel's minimum temperature
current channel's minimum humidity
indoor minimum temperature
indoor minimum humidity
High humidity alert on
indoor
maximum baro reading